Development and Validation of a High-Performance Liquid Chromatography With Ultraviolet Detection Method to Facilitate Therapeutic Monitoring of Teicoplanin Using Dried Blood Spots

Author:

Ramadan Ola,Opitz Patrick,Hempel GeorgORCID

Abstract

Background: In neonatal and pediatric intensive care units, Gram-positive infections are a significant cause of morbidity and mortality. The increase in infections caused by methicillin-resistant Staphylococcus aureus and methicillin-resistant coagulase-negative Staphylococci have led to the increased use of glycopeptides, which treat invasive infections caused by Gram-positive organisms, particularly those resistant to beta-lactam antibiotics. Teicoplanin has bacteriostatic activity against Gram-positive bacteria, but its pharmacokinetics in children is highly variable, with most children failing to reach target levels at the recommended dose. This study aimed to develop a cost-effective method for determining concentrations using dried blood spot (DBS). Methods: A method to determine the concentrations of teicoplanin in 20 µL blood or plasma using the Whatman 903 Protein Saver filter was evaluated. High-performance liquid chromatography with ultraviolet detection high-performance liquid chromatography with ultraviolet/vis was used, with internal standard ketoconazole. In addition, a method to quantify teicoplanin using 50 µL of liquid plasma was established to compare the results with the values obtained by DBS and dried plasma methods. Results: The method was successfully developed and validated for 20 µL DBS. Furthermore, 50 µL of plasma was used to quantify teicoplanin with a lower limit of quantification of 10 mg/L. Precision and accuracy ranged from 2.3% to 10.7% and 95%–114.2%, respectively. A consistent factor (1.15) was used to calculate teicoplanin plasma concentrations from whole blood, indicating the reliability of the DBS method for therapeutic drug monitoring of teicoplanin. Conclusions: A simple, reliable, and cost-effective method using high-performance liquid chromatography with ultraviolet/vis was established to determine pediatric teicoplanin concentrations in both small plasma sample volumes and whole blood using DBS, and an accurate correlation factor for estimating teicoplanin plasma concentrations from DBS was identified. This method is suitable for the use in pediatrics.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3