Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus

Author:

Greenstein Steven A.,Yu Austin S.ORCID,Wawrzusin Peter,Ando Airi,Chung Daniel,Garvey Nicholas,Su Becky,Hersh Peter S.,Gelles John D.

Abstract

Objectives: To report on baseline refractive and keratometric values and their correlation with tomographic characteristics of eyes with keratoconus (KC). Methods: Retrospective chart review of patients treated in a single-center cornea and refractive surgery practice. Baseline topographic measurements were reviewed for 1,012 keratoconic eyes of 586 patients between 2008 and 2018. The manifest refraction, thinnest pachymetry (Pthin), corneal astigmatism (Kastig), and the maximum (Kmax), steep (Ksteep), flat (Kflat), and mean (Kmean) keratometry were analyzed. The location of Kmax (x, y) was used to determine central (<1 mm), paracentral (1–3 mm), pericentral (3–5 mm), or peripheral (>5 mm) cone locations. Results: In the entire cohort, the mean manifest sphere was −2.2±4.4 diopters (D) and the cylinder was −3.2±2.3 D. In total, 48.6% of patients had against the rule (ATR) manifest astigmatism (Mastig). The average Kastig was 3.8±2.7 D, and unlike the manifest axis, 50.2% of patients had with the rule (WTR) Kastig. Patients with a Kmax less than 50 D had an Mastig of −1.9±1.6 D, 45.9% of which was ATR Mastig. With respect to baseline tomography measurements, Kmax, Ksteep, Kflat, and Kmean were 58.0±9.4, 50.6±6.5, 46.8±5.9, and 48.6±6.1 D, respectively. There was a weak correlation between Kmax and simulated keratometry (Ksteep, Kflat, and Kmean) for patients with a Kmax less than 60 D. Conclusions: Simulated keratometry is poorly correlated with KC severity until the disease is more severe. Mastig ≥2 D and ATR Mastig were correlated with KC at all levels of severity. Mastig ≥2 D and ATR Mastig may serve as a simple, inexpensive, and widely available indicator for topographic analysis to identify possible KC and suggest further workup; however, further prospective studies are needed to confirm its utility.

Funder

Research to Prevent Blindness

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Reference22 articles.

1. Keratoconus;Rabinowitz;Surv Ophthalmol,1998

2. Corneal higher order aberrations: A method to grade keratoconus;Alio;J Refract Surg,2006

3. Higher order wavefront aberrations and topography in early and suspected keratoconus;Jafri;J Refract Surg,2007

4. Keratoconus: Classification scheme based on videokeratography and clinical signs;Li;J Cataract Refract Surg,2009

5. Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy;Klyce;Invest Ophthalmol Vis Sci,1984

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3