Evaluation of implantable collamer lens sizing developed by reviewing the horizontal compression-vault coefficient

Author:

Nakamura TomoakiORCID,Nishida Tomoya,Isogai Naoki,Kojima TakashiORCID,Sugiyama Yasuo,Yoshida Yoko

Abstract

Purpose: To evaluate the implantable collamer lens (ICL)–sizing method using the partial regression coefficient of the implanted ICL size to review the conventional horizontal compression coefficient and match the results of clinical observation. Setting: Nagoya Eye Clinic, Nagoya, Japan. Design: Interventional case series. Methods: Patients who underwent ICL V4c implantation to correct myopia and myopic astigmatism were enrolled. The stepwise multiple regression analysis used achieved vault as a dependent variable and preoperative biometric parameters as explanatory variables. The partial regression coefficient of the implanted ICL size was obtained to develop the optimal ICL-sizing formula, the Nakamura-Kojima formula version 3 (NK-formula V3). 85 eyes of 45 patients were implanted with an ICL size recommended by the NK-formula V3. At 3 months postoperatively, the achieved vault was measured using anterior segment optical coherence tomography to validate the NK-formula V3. Results: The study enrolled 174 patients (174 eyes). The partial regression coefficient of the implanted ICL size adopted as the compression-vault coefficient in the multiple regression equation predicting the vault was 0.729. To validate the NK-formula V3, 77 (90.6%), 7 (8.2%), and 1 (1.2%) eyes were in the moderate-vault, low-vault, and high-vault categories, respectively. The mean difference between the achieved and predicted vaults was 0.064 ± 0.190 (range: −0.264 to 0.742) mm for the NK-formula V3 and 0.176 ± 0.217 (range: −0.254 to 0.907) mm for the NK-formula V2. Conclusions: As in vivo coefficient measurement experiments are not possible, the partial regression coefficient is the best option for developing a formula to predict the optimal ICL size.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3