Prospective evaluation of the ESCRS online calculator for calculation of a multifocal intraocular lens

Author:

Lwowski ChristophORCID,Kohnen ThomasORCID

Abstract

Purpose: To evaluate a recently introduced ESCRS online calculator for intraocular lens (IOL) calculation of a multifocal IOL in refractive lens exchange and cataract surgery in a prospective setting. Setting: Department of Ophthalmology, Goethe University Frankfurt, Germany. Design: Prospective, consecutive case series. Methods: Eyes that received lens extraction and multifocal IOL implantation were included. The mean prediction error, mean absolute error, and median absolute prediction error (MedAE) provided by the ESCRS online calculator were compared, as were the number of eyes within ±0.5 diopters (D), ±1.0 D, ±2.0 D of target refraction. The SRK/T formula was also included for comparison. Postoperative spherical equivalent was measured at 3 months. 1 eye per patient was included. Results: 88 eyes from 88 patients with a mean age of 62 ± 9.5 years were included. The MedAE was low for all formulas and ranged from 0.26 D (Kane), Hill-RBF (0.27 D), Hoffer Q Savini/Taroni (Hoffer QST) (0.27 D), Barrett Universal II (BUII) (0.28 D), Emmetropia Verifying Optical (EVO) (0.29 D), Cooke K6 (0.27 D), 0.30 D (Postoperative spherical Equivalent prediction using Artificial intelligence and Linear algorithms, by Debellemaniére, Gatinel, and Saad [Pearl DGS]) to 0.31 D (SRK/T). No statistically significant difference was found (P = .627). Considering the number of eyes within ±0.5 D of the calculated refraction the best performing was again the Hill-RBF (84%, 74 eyes), again followed by Kane (71, 81%), EVO, Pearl DGS, Hoffer QST, BUII (each 80%, 70 eyes), Cooke K6 (78%, 69 eyes), and SRK/T (74%). Again, no statistically significant difference was found (P = .39). Conclusions: Using a recently introduced ESCRS online IOL calculator in multifocal IOLs leds to a high number of eyes reaching target refraction and low prediction errors. All formulas performed similarly well. Hill-RBF showed the highest number of eyes within ±0.5 D, but no significance was found.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Sensory Systems,Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3