Peripheral defocus of monofocal intraocular lenses

Author:

Natarajan BSOpt Ramya1ORCID,Heilman Bianca Maceo23ORCID,Ho Arthur45ORCID,Singh Vivek M.16ORCID,Ruggeri Marco23,Mohamed Ashik1ORCID,Reddy Jagadesh C.6ORCID,Parel Jean-Marie A.23,Vadavalli Pravin K.167ORCID,Manns Fabrice23

Affiliation:

1. Ophthalmic Biophysics Laboratory, L V Prasad Eye Institute, Hyderabad, Telangana, India

2. Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL, USA

3. Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, FL, USA

4. Brien Holden Vision Institute Limited, Sydney, New South Wales, Australia

5. School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia

6. Cataract & Refractive surgery services, L V Prasad Eye Institute, Hyderabad, Telangana, India

7. The Shantilal Shanghvi Cornea Institute, L V Prasad Eye Institute, Hyderabad, Telangana, India.

Abstract

Purpose: To quantify the angular-dependence of monofocal intraocular lens (IOL) power. Setting: Ophthalmic Biophysics Laboratory, Kallam Anji Reddy campus, L V Prasad Eye Institute, Hyderabad, India. Design: Laboratory study. Methods: Experiments were performed on IOLs from two different manufacturers (APPALENS 207, Appasamy Associates and SN60WF, Alcon Laboratories). IOL powers ranged from 17 to 25 D. The IOLs were mounted in a fluid-filled chamber and the on-axis and off-axis powers were measured using a laser ray tracing system over the central 3 mm zone with delivery angles ranging from -30° to +30° in 5° increments. The position of the best focus was calculated for each IOL at each angle. The angular dependence of IOL power was compared with theoretical predictions. Results: Peripheral defocus increased significantly with increasing incidence angle and power. The peripheral defocus at ±30° increased from 5.8 D to 8.5 D when the power increased from 17.5 D to 24.5 D for APPALENS 207 and from 4.9 D to 7.4 D when the power increased from 17 D to 25 D for SN60WF. The mean difference between the measured and theoretical tangential power at ±30° was 0.50 ± 0.16 D for the APPALENS 207 and -0.40 ± 0.10 D for the SN60WF, independent of IOL power. Conclusions: IOLs introduce a significant amount of peripheral defocus which varies significantly with IOL power and design. Given that peripheral defocus is related to lens power, replacement of the natural lens (approximately 24 D) with an IOL will produce a significant difference in peripheral defocus profile after surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3