Affiliation:
1. Department of Radiology, Peking University BinHai Hospital, Tianjin, China.
Abstract
Objective
This study aimed to explore the feasibility and predictive value for local tumor progression (LTP) of the computed tomography (CT)–CT image fusion method versus side-by-side method to assess ablative margin (AM) in hepatocellular carcinoma ≥3 cm in diameter.
Materials and Methods
We selected patients with hepatocellular carcinoma ≥3 cm in diameter who underwent microwave ablation and had complete tumor ablation. We used the CT-CT image fusion method and side-by-side method to assess AM separately and divided the lesions into 3 groups: group I, minimum ablative margin (min-AM) <0 mm (the ablation zone did not fully cover the tumor); group II, 0 mm ≤ min-AM <5 mm; and group III, min-AM ≥5 mm.
Results
A total of 71 patients involving 71 lesions were included. The κ coefficient for the agreement between the CT-CT image fusion method and the side-by-side method in assessing min-AM was 0.14 (P = 0.028). Cumulative LTP rate was significantly different between groups by min-AM from the CT-CT image fusion method (P < 0.05) but not by min-AM from the side-by-side method (P = 0.807). Seventeen of the 20 LTP lesions were located at min-AM on fused CT images, with consistency rate of 85%.
Conclusions
Compared with the side-by-side method, the CT-CT image fusion method is more accurate in assessing the AM of eccentrically ablated lesions and shows better predictive value for LTP. The min-AM based on CT-CT image fusion assessment is an important influencing factor for LTP.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Radiology, Nuclear Medicine and imaging
Cited by
2 articles.
订阅此论文施引文献