Affiliation:
1. Division of Geriatric Musculoskeletal Health and Department of Orthopedic Surgery Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
2. Department of Orthopedic Surgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan
Abstract
Study Design.
Retrospective study.
Objective.
To determine whether an occupancy rate of a pedicle screw (ORPS) <80% in an upper instrumented vertebra (UIV) is a risk factor for UIV fracture (UIVF).
Summary of Background Data.
The ratio of the length of the pedicle screw to the anteroposterior diameter of the vertebral body at the UIV is defined as ORPS. Previous studies showed that the stress on the UIV is reduced to the greatest degree when ORPS is >80%. However, it remains unclear whether these results are clinically valid.
Patients and Methods.
A total of 297 patients who had undergone adult spinal deformity surgery were included in the study. The group with an ORPS ≥80% and <80% was defined as the H (n = 198) and L (n = 99) group, respectively. Propensity score matching and logistic regression analysis were used to evaluate the association between ORPS and the development of UIVF adjusting for confounders.
Results.
The mean age of both groups was 69 years. The average ORPS in the L and H groups was 70% and 85%, respectively. The incidence of UIVF was 30% in group L and 15% in group H (P < 0.01). In addition, the 99 patients in group H were subdivided into 2 groups according to whether the screws penetrated the anterior wall of the vertebral body: 68 patients had no penetration (group U), whereas 31 patients showed evidence of penetration (group B). A total of 10% and 26% of the patients in the U and B groups, respectively, experienced UIVF (P < 0.05). Logistic regression analysis indicated that ORPS <80% was significantly associated with UIVF (P = 0.007, odds ratio: 3.9, 95% CI 1.4–10.5).
Conclusion.
To reduce UIVF, screw length should be set with a target ORPS of 80% or higher. If the screw penetrates the anterior wall of the vertebral body, the risk of UIVF is greater.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Neurology (clinical),Orthopedics and Sports Medicine
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献