Reliability and Agreement of Keratometry Measurements Obtained With Eye Surface Profilometry and Partial Coherence Interferometry

Author:

Martínez-Plaza Elena12,Molina-Martín Ainhoa1,Piñero David P.13ORCID

Affiliation:

1. Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain;

2. University of Valladolid, Valladolid, Spain; and

3. Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain.

Abstract

Purpose: The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device. Methods: Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ESP system. Simulated keratometry in the flat (SimKf) and steep (SimKs) meridians, astigmatism, and axis were obtained. The same parameters were measured using the IOL Master 500 device. The J0 and J45 vector components of the astigmatism were calculated. The intrasession repeatability was analyzed using within-subject SD (Sw) and intraclass correlation coefficient (ICC). Agreement was assessed using paired statistical tests and the Bland–Altman method. Results: The Sw was 0.07 mm, 0.04 mm, 0.51 D, 0.33 D, and 0.22 D, and the ICC was 0.96, 0.98, 0.74, 0.61, and 0.55 for SimKf, SimKs, astigmatism, J0, and J45, respectively. The mean difference and limits of agreement when comparing the ESP system with the IOL Master 500 device were 0.37 mm (0.08/0.66) for SimKf (P < 0.001), 0.18 mm (0.00/0.35) for SimKs (P < 0.001), −0.93 D (−2.42/0.56) for astigmatism (P < 0.001), 0.51 D (−0.22/1.24) for J0 (P < 0.001), and 0.06 D (−0.48/0.60) for J45 (P = 0.09). Conclusions: The ESP system provides consistent values for simulated keratometry, showing moderate consistency for astigmatism parameters. Contact lens practitioners should be aware that the ESP system and IOL Master 500 device provide different simulated keratometry from a clinically viewpoint.

Funder

European Commission

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology

Reference30 articles.

1. Bcla CLEAR: evidence-based contact lens practice;Wolffsohn;Contact Lens Anterior Eye,2021

2. Validation of refraction and anterior segment parameters by a new multi-diagnostic platform (VX120);Gordon-Shaag;J Optom,2018

3. Clinical validation of a new optical biometer for myopia control in a healthy pediatric population;Martínez-Plaza;Children (Basel),2022

4. Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems;Crawford;Am J Ophthalmol,2013

5. Comparison of IOL-Master 700 and IOL-Master 500 biometers in ocular biological parameters of adolescents;Shi;Int J Ophthalmol,2021

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Orthokeratology effect on the corneoscleral profile: Beyond the bull's eye;Ophthalmic and Physiological Optics;2024-01-19

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3