Strategies to Improve the Efficacy of Epicardial Linear Ablation on the Beating Heart

Author:

Watanabe Yoshiyuki1,Schill Matthew R.2,Kazui Toshinobu3,Melby Spencer J.2,Schuessler Richard B.2,Damiano Ralph J.2

Affiliation:

1. Department of Cardiovascular Surgery, Nippon Medical School, Chiba Hokusoh Hospital, Tokyo, Japan

2. Division of Cardiothoracic Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St Louis, MO USA

3. Division of Cardiothoracic Surgery, University of Arizona Medical Center, Tucson, AZ USA.

Abstract

Objective Creating transmural linear lesions on the beating heart is an important component of minimally invasive surgical ablation for atrial fibrillation. Animal studies have shown poor efficacy for surface bipolar radiofrequency ablation (RFA). Clinicians have developed strategies including multiple device applications and vena caval occlusion (VCO) to improve ablation efficacy. These techniques were evaluated in an acute porcine model. Methods In the first experiment, an RFA device was used to perform two 40-second epicardial ablations on the right atrium of six pigs. Ablations were performed with and without VCO. Ultrasonic flow probes were used to verify VCO. In the second experiment, an RFA device was used to perform two 40-second epicardial ablations at six locations on the left and right atria of six pigs. All animals were sacrificed. The hearts were removed and stained with 2,3,5-triphenyltetrazolium chloride. Sections were examined using digital photography. Results With VCO, 42 (81%) of 52 sections were transmural; without VCO on the RA, only 12 (24%) of 50 sections were transmural (P < 0.01). In thick (>2 mm) tissue, 10 (59%) of 17 VCO sections were transmural compared with only two (8%) of 24 with normal caval blood flow. Compared with a single ablation, multiple device applications improved transmurality on the LA but not the RA (92% vs 71%, P < 0.05). Conclusions In an acute animal model, VCO improved the efficacy of beating-heart RFA on the RA. Multiple device applications improved the efficacy of RFA on the LA.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3