Whole Blood Metal Levels in the Setting of an Oncologic Endoprosthesis: Is There Cause for Concern?

Author:

Houdek Matthew T.1ORCID,Couch Cory G.1,Wyles Cody C.1,Taunton Michael J.1,Rose Peter S.1,Kremers Hilal Maradit2,Lewallen David G.1,Berry Daniel J.1

Affiliation:

1. Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA

2. Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN, USA

Abstract

Abstract Background Massive modular endoprostheses have become a primary means of reconstruction after oncologic resection of a lower extremity tumor. These implants are commonly made with cobalt-chromium alloys that can undergo wear and corrosion, releasing cobalt and chromium ions into the surrounding tissue and blood. However, there are few studies about the blood metal levels in these patients. Question/purpose What is the whole blood cobalt and chromium ion level in patients with massive modular endoprostheses? Methods We performed a cross-sectional study of our total joints registry to identify patients with a history of an endoprosthetic reconstruction performed at our institution. Patients who were alive at the time of our review in addition to those undergoing an endoprosthetic reconstruction after an oncologic resection were included. Whole blood samples were obtained from 27 (14 male and 13 female) patients with a history of a lower extremity oncologic endoprosthesis. The median time from surgery to blood collection was 8 years (range 6 months to 32 years). Blood samples were collected and stored in metal-free ethylenediaminetetraacetic acid tubes. Samples were analyzed on an inductively coupled plasma mass spectrometer in an International Organization for Standardization seven-class clean room using polytetrafluoroethylene-coated instruments to reduce the risk of metal contamination. The analytical measuring range was 1 to 200 ng/mL for chromium and cobalt. Cobalt and chromium levels were considered elevated when the blood level was ≥ 1 ppb. Results Cobalt levels were elevated in 59% (16 of 27) of patients, and chromium levels were elevated in 26% (seven of 27). In patients with elevated metal ion values, 15 of 17 patients had a reconstruction using a Stryker/Howmedica Global Modular Replacement System implant. Conclusion Blood metal levels were elevated in patients who received reconstructions using modular oncology endoprostheses Future work is needed to establish appropriate follow-up routines and determine whether and when systemic complications occur because of elevated metal levels and how to potentially address these elevated levels when complications occur. Prospective and retrospective collaboration between multiple centers and specialty societies will be necessary to address these unknown questions in this potentially vulnerable patient group. Level of Evidence Level IV, therapeutic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3