Body Fit With a Pouching System With Concave Contour for People With an Outward Peristomal Body Profile

Author:

Rolfsen Thomas,Vestergaard Martin,Hansen Mads Fuglesang,Boisen Esben Bo,Dambæk Marianne Raff

Abstract

PURPOSE: The purpose of the study was to investigate the fit of a two-piece pouching system with a concave-shaped skin barrier on people with an outward peristomal body profile and its effect on leakage, wear time, and quality of life (QoL) related to using an ostomy product. DESIGN: Randomized, controlled, open-label, cross-over trial. SUBJECTS AND SETTINGS: The sample comprised 53 subjects with outward peristomal body profiles and problems with leakage of ostomy effluent from their pouching system. Participants were randomized to the concave two-piece pouching system or a comparator (two-piece pouching system with a flat skin barrier) for 3 weeks. Subjects were then crossed over to the opposite skin barrier for an additional 3 weeks. The study was conducted in Denmark, Norway, Germany, and the Netherlands; data were collected in multiple ambulatory clinics or during home visits. METHODS: The primary end point was the ability of the skin barrier to fit body contours; secondary outcomes were leakage of effluent from the pouching system, wear time, and QoL related to using an ostomy product via the validated Ostomy-Q questionnaire. Primary comparisons between concave and comparator pouching systems were evaluated using proportional odds models and mixed models taking test period into account. RESULTS: Analysis included randomized subjects who had been exposed to at least one product and with information on at least one end point (full-analysis-set, n = 52). The concave pouching system provided a better fit to body contours than the comparator (P< .001) and reduced the degree of leakage underneath the skin barrier (LS mean difference = −1.84, 95% CI −3.31 to −0.37; P = .016). Participants experienced fewer episodes of leakage outside the skin barrier when using concave versus comparator pouching system (13.0% vs. 26.7%, respectively). Participants reported significant improvements in QoL (LS mean difference = 14.3; 95% CI 9.4 to 19.2; P < .001). No significant difference in wear time between skin barrier shapes was reported. CONCLUSIONS: Study findings indicate that a pouching system with a concave skin barrier achieved a better body fit on people with an outward peristomal body profile and resulted in fewer leakage incidents and higher QoL compared to using a pouching system with a flat skin barrier.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3