Reliability of Respiratory System Compliance Calculation During Assisted Mechanical Ventilation: A Retrospective Study

Author:

Bastia Luca1,Amendolagine Liliana2,Pozzi Federico1,Carenini Stefano1,Cipolla Cristiana1,Curto Francesco1,Bellani Giacomo34,Fumagalli Roberto25,Chieregato Arturo1

Affiliation:

1. Neurointensive Care Unit, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.

2. School of Medicine and Surgery, University of Milano-Bicocca, Monza, Italy.

3. Centre for Medical Sciences—CISMed, University of Trento, Trento, Italy.

4. Department of Anesthesia and Intensive Care, Santa Chiara Regional Hospital, APSS Trento, Trento, Italy.

5. Department of Anesthesia and Intensive Care, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.

Abstract

OBJECTIVES: To compare respiratory system compliance (Crs) calculation during controlled mechanical ventilation (MV) and, subsequently, during assisted MV. DESIGN: This is a single-center, retrospective, observational study. SETTING: This study was conducted on patients admitted to Neuro-ICU of Niguarda Hospital (tertiary referral hospital). PATIENTS: We analyzed every patient greater than or equal to 18 years old having a Crs measurement in controlled and in assisted MV within 60 minutes. Plateau pressure (Pplat) was considered reliable if it was deemed visually stable for at least 2 seconds. Interventions: Inspiratory pause was incorporated to detect Pplat in controlled and assisted MV. Calculation of Crs and driving pressure were achieved. MEASUREMENTS AND MAIN RESULTS: A total of 101 patients were studied. An acceptable agreement was found (Bland-Altman plot bias –3.9, level of agreement upper 21.6, lower –29.6). Crs in assisted MV was 64.1 (52.6–79.3) and in controlled MV it was 61.2 (50–71.2) mL/cm H2 o (p = 0.006). No statistical difference was found in Crs (assisted vs controlled MV) when peak pressure was lower than Pplat nor when peak pressure was higher than Pplat. CONCLUSIONS: A Pplat visually stable for at least 2 seconds leads to reliable Crs calculation during assisted MV.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Is Respiratory System Compliance Calculation During Assisted Mechanical Ventilation Reliable?;Critical Care Medicine;2023-12-14

2. The authors reply:;Critical Care Medicine;2023-12-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3