Chinese Population Reference Curves for Ultrasound-Measured Amniotic Fluid Deepest Vertical Pocket in Dichorionic Twin Pregnancies, and Their Associations With Pregnancy Outcomes

Author:

Lyu Zhengxin,Wu Tianchen,Lu Shan,Yuan Pengbo,Zhao Yangyu,Wei Yuan

Abstract

Abstract Objective To establish the Chinese population's amniotic fluid deepest vertical pocket (DVP) reference curves for dichorionic twin pregnancies and to investigate DVP links with adverse perinatal outcomes. Methods This retrospective cohort study, conducted at Peking University Third Hospital from August 2011 to December 2020, used data from 375 women aged 20 to 45 years who had dichorionic twin pregnancies that were confirmed through first-trimester ultrasound. After exclusions, reference curves were developed using 318 women with 3,299 DVP scans, and the data analyzed included maternal demographics, pregnancy outcomes, ultrasound measurements, and neonatal information. DVPs were assessed via ultrasound at regular intervals and grouped by gestational age (GA) for analyses. Linear mixed models were used to create amniotic fluid reference curves. Associations between abnormalities and adverse perinatal outcomes were examined using Chi-squared or Fisher's exact tests. Logistic regression provided both crude and adjusted odds ratios, adjusting for pre-pregnancy weight, age, ethnicity, parity, and conception mode. Significance was set at P < 0.05 with 95% confidence intervals (CI), and the analyses were conducted using SPSS ver. 26.0 (IBM Corp., Armonk, NY) and SAS ver. 9.4 (SAS Institute Inc., Cary, NC, USA) software. Results DVP increased from the first trimester to a maximum at 26 weeks (95% confidence interval (CI), 2.7–8.3 cm for twin 1 and 2.8–7.9 cm for twin 2) and then decreased gradually toward term. Differences between twins 1 and 2 were significant after 26 weeks (95% CI for twin 1: 5.3, 5.5; 95% CI for twin 2: 4.4, 4.5; P < 0.010). Polyhydramnios of twin 1 increased the risk of large for GA. Oligohydramnios of twin 1 increased the risk of small for GA. Polyhydramnios of twin 2 increased the risk of small for GA, premature birth, and neonatal complications. Oligohydramnios of twin 2 increased the risk of preeclampsia, hypertensive disorder complicating pregnancy, and premature rupture of membranes. Conclusion Reference curves for twin amniotic fluid volumes vary by GA and differ between twins, with potential implications for pregnancy outcomes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Reference22 articles.

1. Controversies in the management of twin pregnancy;Ultrasound Obstet Gynecol,2021

2. Amniotic fluid as a vital sign for fetal wellbeing;Australas J Ultrasound Med,2013

3. Ultrasound evaluation of amniotic fluid volume. I. The relationship of marginal and decreased amniotic fluid volumes to perinatal outcome;Am J Obstet Gynecol,1984

4. Outcome of twin pregnancies complicated by a neural tube defect;Twin Res Hum Genet,2018

5. Ultrasound evaluation of amniotic fluid volume. II. The relationship of increased amniotic fluid volume to perinatal outcome;Am J Obstet Gynecol,1984

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3