Is It Appropriate to Completely Eliminate Contact Shielding during CT Examination? A Discourse Based on Experimental Findings

Author:

Chen Jiwei1,Tu Jianchun2,Huang Shengyan3,Zhu Zhenhua1,Tu Yu

Affiliation:

1. Department of Medical Engineering, Kunshan Hospital of Traditional Chinese Medicine, Kunshan, Jiangsu 215300, P.R. China

2. Department of Radiology, Kunshan Hospital of Traditional Chinese Medicine, Kunshan, Jiangsu 215300, P.R. China

3. Department of Nursing, Kunshan Hospital of Traditional Chinese Medicine, Kunshan, Jiangsu 215300, P.R. China

Abstract

Objective Through the integration of experimental data and literature, this study examines whether complete elimination of contact shielding during CT examination is warranted, with a particular focus on potential impacts to children's thyroid and pregnant women, as well as limitations associated with contact shielding. Methods: The thermoluminescent dosimeter (TLD) tablets were inserted into the phantom's five organs and tissues. Select fixed exposure, automatic exposure control (AEC), and use contact shielding combined into four experimental modes, with scanning of the phantom's four parts. Obtain the absorbed dose measurements within or outside the FOV. Statistical analysis was conducted using SPSS software. Results: (1) The AEC significantly reduces dose within and outside the FOV, with a dose reduction of 40%–60%. (2) The application of contact shielding outside the FOV significantly reduced the dose adjoin the FOV. (3) Both the use of AEC mode and contact shielding can effectively minimize the dose, with a reduction of 50–80%. (4) The shielding within the FOV may introduce image artifacts or interfere with AEC, the implementation of contact shielding outside FOV provides little reduction in radiation exposure risk through previous literature. (5) Contact shielding exhibits certain drawbacks in all aspects. Conclusion: The utilization of AEC mode in clinical CT should be widely adopted to minimize patient radiation exposure. In general, contact shielding both inside and outside the FOV should be avoided during exposure. However for children under 12 years old with thyroid gland examination, contact shielding could maximally reduce external radiation and may be appropriate. Pregnant women require careful evaluation when considering the use of contact shielding. Contact shielding should not be entirely abandoned.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Epidemiology

Reference39 articles.

1. Depression and anxiety during pregnancy and six months postpartum: a follow-up study;Acta Obstet Gynecol Scand,2006

2. Bacterial contamination of lead aprons in a high-volume cardiac catheterization laboratory and disinfection using an automated ultraviolet-c radiation system;J Invasive Cardiol,2018

3. Microbial contamination risk and disinfection of radiation protective garments;Health Phys,2021

4. Clinical issues—April 2021;AORN J,2021

5. Lead aprons are a lead exposure hazard;J Am Coll Radiol,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3