Detection Capability of 89Sr and 90Sr Using Liquid Scintillation Counting

Author:

Blain Ezekiel1,Nishikawa Kimi1,Faye Sherry A.,Roselan Amy1,Burn Adam G.,Torres Miguel A.1,Semkow Thomas M.

Affiliation:

1. Wadsworth Center, New York State Department of Health, Albany, NY 12201

Abstract

Abstract We developed a new method for simultaneous determination of 89Sr and 90Sr with an emphasis on detectability. The samples were digested, and Sr was chemically purified followed by a single count on a liquid scintillation counter in three windows overlapping the 90Sr, 89Sr, and 90Y peaks. Gamma spectrometry was used to measure 85Sr, added for chemical recovery. The method was tested on 18 water samples spiked at levels from 9 to 242 Bq of 89Sr and 90Sr, with either single radionuclides or their mixtures. In addition, eight method blanks were measured. The data were analyzed numerically by solving a system of linear equations for 89Sr and 90Sr activities as analytes and 90Y activity as a participating component. The total uncertainties of the results were calculated numerically using variances and covariances. The average bias from the known activities was −0.3% (range from −3.6 to 3.1%) for 90Sr and − 1.5% (range from −10.1 to 5.1%) for 89Sr. The En -scores were within −1.0 and 1.0 at 95% confidence level. The detection capabilities of this method were determined by means of the decision threshold LC and the limit of detection referred to as the minimum detectable activity. All relevant uncertainties were propagated into the LC and minimum detectable activity. In addition, detection limits were calculated for the purpose of Safe Drinking Water Act monitoring. The detection capabilities were compared with the regulatory requirements in the US and EU for food and water. For samples spiked with either pure 89Sr or 90Sr, false positives were observed for the opposite radionuclide exceeding the above LC values. This was attributed to interference by the spiked activity. A new method was developed to calculate decision and detectability curves in the presence of interference.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Epidemiology

Reference31 articles.

1. Statistical measures of the lower limit of detection of a radioactivity counter;Health Phys,1963

2. Correction to the count-rate detection limit and sample/blank time-allocation methods;Nucl Instr Meth Phys Res,2013

3. Determination of 89Sr and 90Sr radioactive concentrations from least-squares fits to the growth/decay curves;Nucl Instr Meth Phys Res,1992

4. Limits for qualitative detection and quantitative determination, application to radiochemistry;Anal Chem,1968

5. Limiting distribution of random variable being a difference of two independent Poisson random variables;Zastosowania Matematyki,1953

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3