A Survey of Mean Glandular Doses and Suggestions on National Diagnostic Reference Levels for Digital Mammography in China

Author:

Xu Hui1,Yue Baorong1,Cheng Jinsheng1,Deng Jun1,Su Yinping1,Zhao Qiaoqiao1,Xue Ke1,Feng Zechen2,Niu Yantao3,Sun Quanfu1

Affiliation:

1. Key Laboratory of Radiological Protection and Nuclear Emergency Chinese Center for Disease Control and Prevention, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, China

2. Beijing Center for Diseases Prevention and Control, Beijing, China

3. Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Beijing, China

Abstract

Abstract The primary purpose of this study was to report the mean glandular doses and to determine the national diagnostic reference levels for digital mammography based on data between 2016 and 2018 in China. The data from 19,076 mammograms (4,769 examinations) by random sampling from 118 digital mammography systems were compiled. Exposure factors included age, compressed breast thickness, kVp, mAs, target/filter combination, entrance surface air kerma, and mean glandular doses, which were retrospectively surveyed and recorded from the monitor. The national diagnostic reference levels (75th percentiles) in mean glandular dose were calculated across median value obtained for all included data and stratified to specific compressed breast thickness ranges. The patients’ ages ranged from 22 to 88 y, with a median age of 45. The applied voltage and output medians were 28 kVp and 75.1 mAs for all exposure, respectively. The median CBTs were 45 mm and 48 mm for craniocaudal views and mediolateral oblique views, and the corresponding median mean glandular doses were 1.32 mGy and 1.40 mGy, respectively. The national diagnostic reference level at compressed breast thickness of 40–50 mm was 1.67 mGy for CC views and 1.71 mGy for MLO views. The median mean glandular doses varied significantly and increased with compressed breast thickness, demonstrating the necessity of establishing DRL according to breast thickness and optimizing the clinic's digital mammography practice in China.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3