Abstract In a recent study, a comprehensive library composed of 212 phantoms with different body sizes was established by deforming the adult male and female mesh-type reference computational phantoms (MRCPs) of ICRP Publication 145 and the next-generation ICRP reference phantoms over the current voxel-type reference phantoms of ICRP Publication 110. In this study, as an application of the MRCP-based phantom library, we investigated dosimetric impacts due to the different body sizes for neutron external exposures. A comprehensive dataset of organ/tissue dose coefficients (DCs) for idealized external neutron beams with four phantoms for each sex representatively selected from the phantom library were produced by performing Monte Carlo simulations using the Geant4 code. The body size-dependent DCs produced in this study were systematically analyzed, observing that the variation of the body weights overall played a more important role in organ/tissue dose calculations than the variation of the body heights. We also observed that the reference body-size DCs based on the MRCPs indeed significantly under- or overestimated the DCs produced using the phantoms, especially for those much heavier (male: 175 cm and 140 kg; female: 165 cm and 140 kg) than the reference body sizes (male: 176 cm and 73 kg; female: 163 cm and 60 kg) by up to 1.6 or 3.3 times, respectively. We believe that the use of the body size-dependent DCs, together with the reference body-size DCs, should be beneficial for more reliable organ/tissue dose estimates of individuals considering their body sizes rather than the most common conventional approach, i.e., the sole use of the reference body size DCs.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Epidemiology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3