Clinical application of Mycobacterium RT-PCR assay using various specimens for the rapid detection of lymph node tuberculosis: A diagnostic accuracy study

Author:

Zhong Fangming1,Zhao Wuchen1,Wang Linhua2,Shen Yi3ORCID

Affiliation:

1. Zhejiang Tuberculosis Diagnosis and Treatment Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China

2. Department of Hospital Infection, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China

3. Operation Center, Affiliated Hangzhou Chest Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.

Abstract

To evaluate the diagnostic accuracy of the Capital Bio Mycobacterium real-time polymerase chain reaction assay Capital Bio assay for lymph node (LN) tuberculosis (LNTB), and to further compare the effect of different types of LN specimens on the detection capability of the test. We retrospectively analyzed the medical records of LNTB patients who met the inclusion criteria. The sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve of Capital Bio assay were calculated to evaluate its diagnostic accuracy compared with the final clinical diagnosis as reference standard. Three hundred sixty-four patients were included in the study. The overall sensitivity, specificity, positive predictive value, negative predictive value, and area under the curve of the Capital Bio assay for LNTB were 74.4%, 100.0%, 100.0%, 34.9%, and 0.87, respectively. For the pus specimens, these values for Capital Bio assay were 93.2%, 100.0%, 100.0%, 27.3%, 0.97, respectively. For the core needle biopsy specimens, these values were 65.9%, 100.0%, 100.0%, 33.3%, and 0.83, respectively. For the fine-needle aspiration specimens, these values were 60.0%, 100.0%, 100.0%, 53.9%, and 0.80, respectively. For the tissue, these values were 59.3%, 100.0%, 100.0%, 33.3%, 0.80, respectively. The Capital Bio assay had good effective for the diagnosis of LNTB. Compared to LN fine-needle aspiration and core needle biopsy specimens and tissue specimens, pus specimens were more suitable for molecular testing and had the best diagnostic efficacy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3