CPR quality with rotation of every 1 versus 2 minutes as characteristics of rescuers: A randomized crossover simulation study

Author:

Kim Dong Hun1,Seo Young Woo2,Jang Tae Chang2ORCID

Affiliation:

1. Department of Emergency Medical Technology, Gyeongbuk Provincial College, Gyeongsangbuk-do, Republic of Korea

2. Department of Emergency Medicine, School of Medicine, Daegu Catholic University, Daegu, Republic of Korea.

Abstract

Background: Fatigue and rotation time are key factors affecting the quality of cardiopulmonary resuscitation (CPR). This study aimed to investigate the effects of rotation time on CPR duration, and sex on chest compression quality. Methods: In this randomized crossover simulation study, we enrolled 100 paramedic students stratified by sex and randomly grouped into 28 male and 22 female pairs. In the 2- and 1-minute scenarios, 2 participants performed CPR for 20 minutes with a rotation cycle of 2 minutes and 1 minute, respectively. After taking a break, they changed over and performed CPR again for 20 minutes. The switching of roles was performed with the students positioned on opposite sides of the mannequin. For chest compression quality, a set was defined as CPR performed by 1 pair in a 2-minute scenario for 4 minutes. The quality of CPR in each set was compared between the 2 groups. Results: The 1-minute group showed significantly higher chest compression depth than the 2-minute group (54.0 [51.5–57.0] vs 52.5 [48.5–56.5] mm, P = .001, respectively). The female 2-minute group showed decreased chest compression depth over time, and the 1-minute group showed significantly increased chest compression depth during all sets except the 2nd set (54.0 [51.9–55.1] vs 50.5 [48.5–53.8] mm [P = .030], 52.3 [49.4–54.5] vs 50.8 [47.0–53.1] mm [P = .080], 52.8 [49.8–54.5] vs 48.8 [45.4–51.6] mm [P = .002], 51.5 [48.5–53.3] vs 48.3 [44.5–50.6] mm [P = .004], and 50.8 [48.9–54.1] vs 47.5 [44.6–50.1] mm [P = .001], respectively). The fatigue scores in the 2-minute group were significantly higher during sets 4 and 5 than those in the 1-minute group. Conclusion: When rescuer fatigue increases during prolonged CPR owing to their physical strength and skill levels, the rotation of rescuers every minute would be helpful in maintaining high-quality CPR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference22 articles.

1. Decay in quality of closed-chest compressions over time.;Hightower;Ann Emerg Med,1995

2. European resuscitation council guidelines for resuscitation 2015: section 2. Adult basic life support and automated external defibrillation.;Perkins;Resuscitation,2015

3. Part 1: executive summary: 2020 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care.;Raina;Circulaton,2020

4. Relationship between weight of rescuer and quality of chest compression during cardiopulmonary resuscitation.;Tomoyuki;J Physiol Anthropol,2014

5. Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest.;Abella;JAMA,2005

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献