The efficacy and safety of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee arthroplasty: Evidence from a meta-analysis

Author:

Wang Huihui1,Zhang Liang1,Teng Xueren1ORCID

Affiliation:

1. Qingdao Eighth People’s Hospital, Qingdao, China.

Abstract

Background: The aim of this study was to compare the efficacy and safety of patient-specific instrumentation (PSI) and conventional instrumentation (CI) for unicompartmental knee arthroplasty. Our hypothesis was that the PSI would be superior to CI in improving implant positioning and clinical function. Methods: We searched electronic databases (PubMed, Web of Science, Embase, and Cochrane) to identify relevant studies published before July 1, 2023 that met our inclusion criteria. The identified reports at least included one of the following outcome variables: coronal component alignment, sagittal component alignment, number of outliers, hip-knee-ankle angle, postoperative complications, operative time and knee joint functional evaluation. For dichotomous variables, we calculated the risk ratio and its 95% confidence interval (CI). For continuous variables, we calculated the mean difference (MD) and its 95% CI. Heterogeneity of the included studies was assessed using the standard chi-square test. Meta-analyses were performed using RevMan 5.4. software. The meta-analysis was registered with PROSPERO (No. CRD42023454160). Results: A total of 9 articles were included in the analysis, consisting of 4 randomized controlled trials and 5 cohort studies. The study population comprised 494 patients, with 262 in the PSI group and 232 in the CI group. Our findings demonstrate that the PSI group exhibits superior tibial component coronal alignment compared to the CI group (MD = −0.66, 95% CI: −1.21 to −0.12, P = .02). Conversely, the CI group demonstrates better femoral component coronal alignment than the PSI group (MD = 0.89, 95% CI: 0.17–1.60, P = .01). No significant between 2 groups differences were observed in tibial component sagittal alignment, femoral component sagittal alignment, tibial coronal axis outliers, tibial sagittal axis outliers, femoral coronal axis outliers, femoral sagittal axis outliers, postoperative complications, operative time, hip-knee-ankle angle, and postoperative knee joint function score. Conclusions: Our study findings suggest that the PSI confer an advantage in achieving superior tibial component coronal alignment, whereas the CI associated with better femoral component coronal alignment. However, no significant differences were observed between the groups in terms of other parameters. Future studies with larger sample sizes are needed to validate these findings.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3