Purpose:
To study the performance of artificial intelligence (AI) for detecting pleural pathology on chest radiographs (CXRs) using computed tomography as ground truth.
Patients and Methods:
Retrospective study of subjects undergoing CXR in various clinical settings. Computed tomography obtained within 24 hours of the CXR was used to volumetrically quantify pleural effusions (PEfs) and pneumothoraxes (Ptxs). CXR was evaluated by AI software (INSIGHT CXR; Lunit) and by 3 second-year radiology residents, followed by AI-assisted reassessment after a 3-month washout period. We used the area under the receiver operating characteristics curve (AUROC) to assess AI versus residents’ performance and mixed-model analyses to investigate differences in reading time and interreader concordance.
Results:
There were 96 control subjects, 165 with PEf, and 101 with Ptx. AI-AUROC was noninferior to aggregate resident-AUROC for PEf (0.82 vs 0.86, P < 0.001) and Ptx (0.80 vs 0.84, P = 0.001) detection. AI-assisted resident-AUROC was higher but not significantly different from the baseline. AI-assisted reading time was reduced by 49% (157 vs 80 s per case, P = 0.009), and Fleiss kappa for Ptx detection increased from 0.70 to 0.78 (P = 0.003). AI decreased detection error for PEf (odds ratio = 0.74, P = 0.024) and Ptx (odds ratio = 0.39, P < 0.001).
Conclusion:
Current AI technology for the detection of PEf and Ptx on CXR was noninferior to second-year resident performance and could help decrease reading time and detection error.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Pulmonary and Respiratory Medicine,Radiology, Nuclear Medicine and imaging
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献