Waterproof Hip Spica Casts for Pediatric Femur Fractures

Author:

Churchill Jessica L.1,Kronk Trinity A.23,Adamczyk Mark J.3,Brown Miraides F.4,Ritzman Todd F.3,Floccari Lorena V.3

Affiliation:

1. Department of Orthopedics, Cleveland Clinic Foundation, Cleveland

2. Department of Anatomy and Neurobiology, Northeast Ohio Medical University, Rootstown

3. Department of Orthopedics, Akron Children’s Hospital

4. Akron Children’s Hospital, Rebecca D. Considine Research Institute, Akron, OH

Abstract

Background: Hip spica casting is the treatment of choice for femur fractures in children ages 6 months to 5 years. Traditional spica (TS) casting utilizes cotton padding that precludes patient bathing. Waterproof (WP) casting has inherent advantages, including clearance for bathing and improved family satisfaction. This study examines the safety and efficacy of WP hip spica casting for the treatment of pediatric femur fractures. Methods: This is a retrospective, matched cohort study of patients ≤5 years with a femur fracture treated with hip spica casting. Patients with WP casts were matched to patients with TS casts by age, sex, and fracture type. TS casts utilize a Goretex liner and cotton padding, while WP spicas utilize fully WP materials and can be completely submerged in water. Results: Fifty patients were included (25 WP, 25 TS) without differences between cohorts in age, weight, or sex. There were no differences in operative time, length of stay, or length of time in cast. Patient charges were significantly lower in the WP group ($230 vs. $301, P<0.001). At cast-off, coronal/sagittal alignment and shortening were similar, while 9 TS patients had minor skin and/or cast complications that required outpatient repair versus only 1 WP patient (P<0.001). Conclusions: In a matched comparison, WP spica casting significantly reduces skin and cast complications traditionally associated with cotton-based spica casting, with significantly lower charges for WP cast materials. Fracture healing rate, alignment, and shortening at cast-off are similar in WP versus TS casts. WP spica casting is safe and efficacious for pediatric femur fractures, with the inherent advantage of clearance for bathing. Level of Evidence: Level 3.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Reference21 articles.

1. Incidence of skin complications and associated charges in children treated with hip spica casts for femur fractures;DiFazio;J Pediatr Orthop,2011

2. Spica cast application in the emergency room for select pediatric femur fractures;Cassinelli;J Orthop Trauma,2005

3. Interpretation of American Academy of Orthopaedic Surgeons Clinical Practice Guideline on the treatment of pediatric diaphyseal femur fractures;Chen;Zhonghua Wai Ke Za Zhi,2017

4. The treatment of pediatric femur fractures with early 90-90 spica casting;Czertak;J Pediatr Orthop,1999

5. AAOS Clinical Practice Guideline on the treatment of pediatric diaphyseal femur fractures;Jevsevar;J Am Acad Orthop Surg,2015

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Bracing for Pediatric Femoral Shaft Fractures;Journal of the Pediatric Orthopaedic Society of North America;2024-08

2. Children’s orthopaedics;Bone & Joint 360;2024-02-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3