Does the Use of Probe-based Near-infrared Autofluorescence Parathyroid Detection Benefit Parathyroidectomy?

Author:

Kiernan Colleen M.1,Thomas Giju23,Patel Anuradha1,Fan Run4,Ye Fei4,Willmon Parker A.23,Solórzano Carmen C.13

Affiliation:

1. Division of Surgical Oncology and Endocrine Surgery, Vanderbilt University Medical Center, Nashville, TN

2. Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN

3. Department of Biomedical Engineering, Vanderbilt University, Nashville, TN

4. Department of Biostatistics, Vanderbilt University, Nashville, TN

Abstract

Objective: To evaluate the benefits of probe-based near-infrared autofluorescence (NIRAF) parathyroid identification during parathyroidectomy. Background: Intraoperative parathyroid gland identification during parathyroidectomy can be challenging, while additionally requiring costly frozen sections. Earlier studies have established NIRAF detection as a reliable intraoperative adjunct for parathyroid identification. Methods: Patients undergoing parathyroidectomy for primary hyperparathyroidism were prospectively enrolled by a senior surgeon (>20 years experience) and a junior surgeon (<5 years experience), while being randomly allocated to the probe-based NIRAF or control group. Data collected included procedure type, number of parathyroids identified with high confidence by the surgeon and the resident, number of frozen sections performed, parathyroidectomy duration, and number of patients with persistent disease at the first postoperative visit. Results: One hundred sixty patients were randomly enrolled under both surgeons to the probe group (n=80) versus control (n=80). In the probe group, parathyroid identification rate of the senior surgeon improved significantly from 3.2 to 3.6 parathyroids per patient (P<0.001), while that of the junior surgeon also rose significantly from 2.2 to 2.5 parathyroids per patient (P=0.001). Parathyroid identification was even more prominent for residents increasing significantly from 0.9 to 2.9 parathyroids per patient (P<0.001). Furthermore, there was a significant reduction in frozen sections utilized in the probe group versus control (17 vs 47, P=0.005). Conclusion: Probe-based NIRAF detection can be a valuable intraoperative adjunct and educational tool for improving confidence in parathyroid gland identification, while potentially reducing the number of frozen sections required.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3