The effect of surface-modified silver nanoparticles on the inflammatory component of the intragingival peri-implant area

Author:

Maksymov D. Ya.ORCID,Mishchenko O. M.ORCID

Abstract

Aim: to evaluate the intensity of the gingival inflammatory component in the peri-implant area by studying the mucous membrane bleeding in the implant area according to the papilla bleeding index (PBI), when using healing abutments with a surface modified with silver nanoparticles (AgNP). Materials and methods. 40 patients undergoing rehabilitation for secondary partial adentia by the method of dental implantation were enrolled in the study and divided into 2 groups: Group 1 (20 patients) – healing abutments with the surface modified by the method of plasma electrooxidation and AgNP-doped were fixed; Group 2 (20 patients) – standard healing abutments of the implant system used with a polished surface were fixed. The control group (20 patients) – to determine reference values. A total of 60 patients were involved in the study. The degree of bleeding was measured according to the PBI. The mucous membrane thickness was assessed using an endodontic reamer. Results. There was no statistically significant difference in bleeding level 0 between Groups 1 and 2, but the study group was significantly different from the control group (p < 0.001). According to the bleeding level 3, there was a statistically significant difference between Groups 1 and 2, the study group was (12.7 %) versus 48.5 % (p < 0.001). In addition, the study group was significantly different from the control group (p = 0.019), but this was due to the fact that the measurements were taken directly from the wound surface and the comparison was made to understand inflammatory manifestations as a whole. According to bleeding level 4, there were no patients with this level in the study group, but in the comparison group there were 19.2 % of those (p < 0.001). Based on the results of the data obtained, it is advisable to consider effective use of the antibacterial effect of silver nanoparticles to reduce the gingival inflammatory component in the peri-implant area. Conclusions. The use of the bleeding index (PBI) is appropriate in the clinical diagnosis of inflammatory processes in the peri-implant area. Reduction of levels 3, 4 bleeding in the peri-implant area by 35.8 % and 19.2 %, respectively, in patients using healing abutments coated with AgNP compared to polished ones, indicates a pronounced anti-inflammatory effect of the proposed AgNP-doped surface. The absence of a statistical difference in the mucous membrane thickness of the studied areas between the groups allows us to consider the obtained results as consequences of the silver nanoparticle impact with an antibacterial effect. The result of this study allows recommending the proposed AgNP-doped surface for use in clinical practice.

Publisher

Zaporizhzhia State Medical and Pharmaceutical University

Subject

General Earth and Planetary Sciences,General Engineering,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3