Abstract
Background Dentocraniofacial asymmetry is a common condition that affects many individuals. Accurate diagnosis of this condition is essential for effective treatment planning. Aim This study aimed to compare the diagnosis of dentocraniofacial asymmetry using two-dimensional and three-dimensional methods. Methods A cross-sectional, observational study was conducted at the Orthodontic Specialist Clinic of the Dental Hospital Faculty of Dentistry, University of Indonesia from March to April 2023. The study included 15 patients who had not undergone orthodontic treatment and were diagnosed with dentocraniofacial asymmetry. The study compared the results of diagnosing asymmetry in 15 different facial features, including the anterior nasal spine, upper and lower first incisors, pterygomaxillary fissure, orbita, menton, porion, upper and lower first molars, coronoid process, gonion, zygoma, latero nasale, and jugulare. Results The study found that there was no significant difference in the diagnosis of dentocraniofacial symmetry between the two- and three-dimensional methods across all 15 parameters measured. The researchers used Fisher's Exact Test to compare the proportion between dependent variables and found that the p-value was greater than 0.05, indicating that there was no significant difference in the diagnosis of dentocraniofacial symmetry between the two methods. The study also used Kappa Cohen analysis to measure the strength of agreement between the diagnosis of dentocraniofacial symmetry of the two-dimensional and three-dimensional methods on each parameter. Conclusion The findings of this study suggest that both two-dimensional and three-dimensional methods are equally effective in diagnosing dentocraniofacial asymmetry. This information may be useful for orthodontists in deciding which method to use when diagnosing dentocraniofacial asymmetry.
Reference11 articles.
1. Comparison of conventional and cone beam CT synthesized cephalograms.;V Kumar;Dentomaxillofac. Radiol.,2007 Jul
2. DVT- und MSCT-gestützter Vergleich der Reproduzierbarkeit anatomischer Messpunkte: Eine In-vitro-Studie.;J Medelnik;J. Orofac. Orthop.,2011
3. Suitability and accuracy of CBCT model scan: an in vitro study.;J Robben;Int. J. Comput. Dent.,2017
4. 3D-CT evaluation of facial asymmetry.;A Katsumata;Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod.,2005 Feb
5. Accuracy of the measurements from multiplanar and sagittal reconstructions of CBCT.;M Barreto;Orthod. Craniofac. Res.,2020 May