The quantified method for blood clot detection in the extraction socket

Author:

Tanya SuwatORCID,Patcharanuchat Piyachat,Sattayut SajeeORCID

Abstract

Background Currently, there is no objective and quantified measurement for detecting blood clots during extraction socket hemostasis. It has relied solely on clinical observation, even when conducting clinical research by using extraction sockets as samples. This study aimed to assess the in vitro reliability and clinical-relevant validity of a new objective measurement providing quantified data called blood clot detection (BCD) using a standard capillary tube. Methods The in vitro part of the study was conducted using surplus blood samples from ten healthy participants. Two identical sets of blood samples in simulation reservoirs mimicking bleeding sockets were prepared for reliability tests. Then, the capillary tubes were concurrently placed in the reservoirs. The blood-filled distances were measured. The part of clinical-relevant validity study was conducted in sixteen extraction sockets from each healthy participant. Clinical observation and BCD measurement were evaluated by two calibrated assessors. The total duration of the assessment was a 30-minute. Results The distances of the blood-filled capillary tube were decreased by time. Test and retest reliability analysis of the BCD measurement showed an excellent intraclass correlation coefficient of 0.980 (0.968 to 0.988). The medians of blood-filled distance categorized by clinical observation into active bleeding, sluggish oozing, and clot formation were 13.0 mm (Q1 = 11.7, Q3 = 13.8), 5.6 mm (Q1 = 4.3, Q3 = 7.0), and 0.9 mm (Q1 = 0.5, Q3 = 1.3), respectively. The blood-filled distance of the clot formation group was significantly less than the active bleeding and sluggish oozing (p<0.001). Therefore, the BCD measurement also significantly indicated the completion of extraction socket hemostasis Conclusions A distance of blood-filled in capillary tube of 0.9 mm from the BCD measurement significantly ensured complete clot formation. The BCD measurement proved to be a quantified tool for objectively measuring hemostasis of bleeding socket.

Funder

the Fundamental Fund (2024) of Khon Kaen University and the Lasers in Dentistry Research Group, Khon Kaen, Thailand.

Publisher

F1000 Research Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3