Simulation-guided Development of an Optical Calorimeter for High Dose Rate Dosimetry

Author:

Roberts Jackson1ORCID,Moggre Alicia1,Meyer Juergen2,Marsh Steven3

Affiliation:

1. Te Whatu Ora Health New Zealand Waitaha Canterbury

2. University of Washington Medical Center

3. University of Canterbury Department of Chemistry: University of Canterbury School of Physical and Chemical Sciences

Abstract

Abstract PURPOSE Optical Calorimetry (OC) is based on interferometry and provides a direct measurement of spatially resolved absorbed dose to water by measuring refractive index changes induced by radiation. The purpose of this work was to optimize and characterize in software an OC system tailored for ultra-high dose rate applications and to build and test a prototype in a clinical environment. METHODS A radiation dosimeter using the principles of OC was designed in optical modelling software. Traditional image quality instruments, fencepost and contrast phantoms, were utilized in both software and experimentally in a lab environment to investigate noise reduction techniques and to test the spatial and dose resolution of the system. Absolute dose uncertainty was assessed by measurements in a clinical 6 MV flattening filter free (FFF) photon beam with dose rates in the range 0.2–6 Gy/s achieved via changing the distance from the source. RESULTS Design improvements included: equalizing the pathlengths of the interferometer, isolating the system from external vibrations and controlling the system’s internal temperature as well as application of mathematical noise reduction techniques. Simulations showed that these improvements should increase the spatial resolution from 22 to 35 lp/mm and achieve a minimum detectable dose of 0.2 Gy, which was confirmed experimentally. In the FFF beam, the absolute dose uncertainty was dose rate dependent and decreased from 2.5 ± 0.8 Gy to 2.5 ± 0.2 Gy for dose rates of 0.2 and 6 Gy/s, respectively. CONCLUSIONS A radiation dosimeter utilizing the principles of OC was developed and constructed. Optical modelling software and image quality phantoms allowed for iterative testing and refinement. The refined OC system proved capable of measuring absorbed dose to water in a linac generated photon beam. Reduced uncertainty at higher dose rates indicates the potential for OC as a dosimetry system for high dose rate techniques such as microbeam and ultra-high dose-rate radiotherapy.

Publisher

Research Square Platform LLC

Reference17 articles.

1. Absorbed dose calorimetry;Renaud J;Phys Med Biol,2020

2. The UK primary standard calorimeter for photon-beam absorbed dose measurement;DuSautoy AR;Phys Med Biol,1996

3. A Holographic Interferometer for Measuring Radiation Energy Deposition Profiles in Transparent Liquids;Hussmann EK;Appl Opt,1971

4. Interferometer for measuring fast changes of refractive index and temperature in transparent liquids;Miller A;Rev Sci Instrum,1975

5. Kreis T (2006) Handbook of Holographic Interferometry Optical and Digital Methods. https://nbn-resolving.org/urn:nbn:de:101:1-201408135695

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3