3D-printed Patient-Specific Implants made of Polylactide (PLDLLA) and β-Tricalcium Phosphate (β-TCP) for Corrective Osteotomies of The Distal Radius

Author:

Jakimiuk Adam1,Maintz Michaela1,Müller-Gerbl Magdalena2,Thieringer Florian M.1,Keller Marco1,Guebeli Alissa3,Honigmann Philipp1

Affiliation:

1. Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland

2. Anatomical Institute, Department of Biomedicine, University of Basel, Basel, Switzerland

3. Department of Plastic Surgery and Hand Surgery, Cantonal Hospital Aarau, Aarau, Switzerland

Abstract

Abstract The most common surgical procedure to manage the malunion of the bones is corrective osteotomy. The current gold standard for securing the bone segments after osteotomy is the use of titanium plates and allografts which has disadvantages such as possible allergic reaction, additional operations such as extraction of the graft from other sites and removal operation. The utilization of resorbable materials presents an opportunity to mitigate these drawbacks, but has not yet been thoroughly researched in literature. This study assesses viability of using biodegradable, 3D-printed patient-specific implants made of Poly(-L-lactide-co-D,L-lactide) (PLDLLA) and β-Tricalcium Phosphate (β-TCP) as an alternative material in an in-vitro biomechanical study involving ex vivo biomechanical compression testing, biodegradation testing, and calorimetric measurements.. These implants possess a unique shape, resembling a wedge and are fixated as a connection between the osteotomized bone using resorbable screws. Following point-of-care virtual planning, bio-mechanical compressive tests with (n = 5) ex vivo radii equipped with PLDLLA/ β-TCP implants were performed to prove sufficient stability of the connection. All PLDLLA/ β-TCP implants withstood a compressive force of at least 1’211 N which exceeds the maximum force reported in literature in case of a fall from the height of 1 m. Furthermore, the results showed a consistent surface chemistry and slow degradation rate. The outcomes are encouraging, establishing the groundwork for an innovative distal radius corrective osteotomy surgical method. However, further research is necessary to thoroughly evaluate the long-term biodegradability and mechanical efficacy of the implants.

Publisher

Research Square Platform LLC

Reference31 articles.

1. Malunion of the Distal Radius;Bushnell BD;J Am Acad Orthop Surg

2. Effects of distal radius fracture malunion on wrist joint mechanics;Pogue DJ;J Hand Surg Am

3. Distal Radius Fractures;Liporace FA;J Orthop Trauma

4. Distal Radius Malunion;Katt B;J Hand Surg Am

5. Titanium–Tissue Interface Reaction and Its Control With Surface Treatment;Hanawa T;Front Bioeng Biotechnol

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3