Image Denoising of Low Dose PET Mouse Scans with Deep Learning: Validation Study for Cross-Tracer Preclinical Imaging Applicability

Author:

Muller Florence Marie1ORCID,Vervenne Boris1,Maebe Jens1,Blankemeyer Eric2,Sellmyer Mark A.2,Zhou Rong2,Karp Joel S.2,Vanhove Christian1,Vandenberghe Stefaan1

Affiliation:

1. Ghent University Faculty of Engineering and Architecture: Universiteit Gent Faculteit Ingenieurswetenschappen en Architectuur

2. University of Pennsylvania Department of Radiology

Abstract

Abstract Purpose: Positron Emission Tomography (PET) image quality can be improved by higher injected activity and/or longer acquisition time, but both may often not be practical in preclinical imaging. Common preclinical radioactive doses (10 MBq) have been shown to cause deterministic changes in biological pathways. Reducing the injected tracer activity and/or shortening the scan time inevitably results in low-count acquisitions which poses a challenge because of the inherent noise introduction. We present an image-based deep learning (DL) framework for denoising lower count micro-PET images. Procedures: For 36 mice, a 15-min 18F-FDG (8.15 ± 1.34 MBq) PET scan was acquired at 40 min post-injection on the Molecubes b-CUBE (in list mode). The 15-min acquisition (high-count) was parsed into smaller time fractions of 7.50, 3.75, 1.50 and 0.75 mins to emulate images reconstructed at 50, 25, 10 and 5% of the full counts, respectively. A 2D U-Net was trained with mean-squared-error loss on 28 high-low count image pairs. Results: The DL algorithms were visually and quantitatively compared to spatial and edge-preserving denoising filters; the DL-based methods effectively removed image noise and recovered image details much better while keeping quantitative (SUV) accuracy. The largest improvement in image quality was seen in the images reconstructed with 10 and 5% of the counts (equivalent to sub-1-MBq or sub-1-min mouse imaging). The DL-based denoising framework was also successfully applied on the NEMA-NU4 phantom and different tracer studies (18F-PSMA, 18F-FAPI and 68Ga-FAPI). Conclusion: Visual and quantitative results support the superior performance and robustness in image denoising of the implemented DL models for low statistics micro-PET. This offers tremendous flexibility in optimizing scan protocols with reduced tracer doses or shorter durations.

Publisher

Research Square Platform LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3