Affiliation:
1. Universidade Federal do Recôncavo da Bahia, Cruz das Almas
2. National University of Cuyo
3. Universidade Federal do Oeste da Bahia, Centro Multidisciplinar de Bom Jesus da Lapa
4. Universidade Federal da Bahia
Abstract
Abstract
The microwave-induced plasma optical emission spectrometer has been used for multielement determination in South American wine samples. The analytes were determined after acid digestion of 47 samples of Brazilian and Argentine wine and the application of logistic regression, support vector machine, and decision tree for exploratory analysis and the comparison of these algorithms in differentiating red wine samples by region of origin. The Brazilian wines samples were clustering in a group, while Argentines wines samples formed another cluster. The quantification limits (mg L-1) were P (0.06); B (0.08); K (0.17); Mn (0.002); Cr (0.002) and Al (0.02). The accuracy of the method was evaluated analyzing the wine samples by ICP OES for results comparison. The concentration in mg L-1 found for each element in wine samples, were Al (< 0.02 - 1.82), Cr (0.15 - 0.50), Mn (< 0.002 - 0.8), P (97 - 277), B (1.7 - 11.6), Pb (< 0.06 - 0.3), Na (8.84 - 41.57) and K (604 - 1701), in mg L-1.
Publisher
Research Square Platform LLC