Outcomes after revision of anatomic total shoulder arthroplasty to reverse shoulder arthroplasty and comparison between cemented or metal-backed glenoid in platform systems.

Author:

Zampeli Frantzeska1,Kazum Efi2,Gomez Alejandro3,Valenti Philippe3

Affiliation:

1. Hand, Upper Limb & Microsurgery Department, KAT Attica General Hospital, Kifisia

2. Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv

3. Paris shoulder unit, Clinique Bizet, Paris

Abstract

Abstract

Background The objective of this study is to report the outcomes after revision of anatomical total shoulder arthroplasty (ATSA) to reverse shoulder arthroplasty (RSA) and to compare between groups depending on the primary ATSA glenoid implant type, cemented polyethylene (PE) versus a convertible metal-backed (MB). The hypothesis was that the outcomes would differ between patients treated with ATSA with PE and MB implants in favor of the platform system. Methods Group A included ten cases of convertible MB glenoid that were revised due to instability (six cases), posterosuperior rotator cuff tear (RCT) (two cases), subscapularis rupture (one case) and polyethylene dissociation (one case); Group B included ten cases of cemented PE that were revised due to glenoid loosening (six cases), RCT (two cases), dislocation (one case), and painful stiffness (one case). Active motion, Constant score, subjective shoulder value, Simple Shoulder Test and pain (VAS) were evaluated at minimum follow-up of two years. Student’s t test and Mann-Whitney tests were used for statistical analysis. Level of significance α=0.05. Results For the entire study cohort, postoperative results were improved compared to the preoperative state (p<0.05) at mean follow-up 60 months (24-188). Group A demonstrated improved postoperative pain levels compared to Group B (VAS 0.1 vs 1.9; p=0.004). No other differences were detected between the two groups (p>0.05). One complication occurred in Group B where one patient was re-operated for RSA instability with a good final functional outcome. Conclusions ATSA to RSA conversion resulted in improved functional outcomes. Post RSA motion and functional outcomes did not differ between the two groups with exception of reduced pain levels for patients treated with a convertible MB ATSA system. Level of evidence: III; retrospective comparative study; treatment study

Publisher

Springer Science and Business Media LLC

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3