Affiliation:
1. Changzhou No.2 People's Hospital
2. The People's Hospital of Ma Anshan
3. The First People's Hospital of Lianyungang
Abstract
Abstract
Aim
To evaluate the diagnostic accuracy of improved fluoroscopy-guided biopsies for indeterminate biliary strictures (IBDS).
Methods
A multi-center retrospective study was performed. Patients with IBDS who underwent digital single-operator cholangioscopy (DSOC) and improved fluoroscopy-guided biopsies procedures were included. The individual sensitivity, specificity, and accuracy were analyzed.
Results
A total of 67 patients were enrolled in this multi-center retrospective study. The DSOC and improved fluoroscopy-guided biopsies procedures were successfully performed in all cases (100%). The sensitivity, specificity, and accuracy values were 83.3%, 89.5%, and 85.1% for DSOC visual impression; 95.8%, 94.7%, and 95.5% for improved fluoroscopy-guided biopsies procedures, respectively. The sensitivity and accuracy of improved fluoroscopy-guided biopsies were significantly higher compared with DSOC visual impression. Four patients (6.0%, 4/67) occurred adverse events after the procedures.
Conclusions
Improved fluoroscopy-guided biopsies had a high diagnostic accuracy of IBDS diagnosis.
Publisher
Research Square Platform LLC