‘Watkins’ & ‘Watkins2.0’: Smart Phone Applications (Apps) For Gait- Assessment in Normal Pressure Hydrocephalus And Decompensated Long-Standing Overt Ventriculomegaly

Author:

Tariq Kanza1,Thorne Lewis1,Toma Ahmed1,Watkins Laurence1

Affiliation:

1. National Hospital for Neurology and Neurosurgery

Abstract

Abstract

Objective Gait disturbance is one of the features of normal pressure hydrocephalus (NPH) and decompensated long-standing overt ventriculomegaly (LOVA). The timed-up-and-go (TUG) test and the timed-10-meter-walking test (10MWT) are frequently used assessments tools for gait and balance disturbances in NPH and LOVA, as well as several other disorders. We aimed to make smart-phone apps which perform both the 10MWT and the TUG-test and record the results for individual patients, thus making it possible for patients to have an objective assessment of their progress. Patients with a suitable smart phone can perform repeat assessments in their home environment, providing a measure of progress for them and for their clinical team. Methods 10MWT and TUG-test were performed by 50 healthy adults, 67 NPH and 10 LOVA patients, as well as 5 elderly patients as part of falls risk assessment using the Watkins2.0 app. The 10MWT was assessed with timed slow-pace and fast-pace. Statistical analysis used SPSS (version 25.0, IBM) by paired t-test, comparing the healthy and the NPH cohorts. Level of precision of the app as compared to a clinical observer using a stopwatch was evaluated using receiver operating characteristics curve. Results As compared to a clinical observer using a stopwatch, in 10MWT the app showed 100% accuracy in the measure of time taken to cover distance in whole seconds, 95% accuracy in the number of steps taken with an error ± 1–3 steps, and 97% accuracy in the measure of total distance covered with error of ± 0.25–0.50 meter. The TUG test has 100% accuracy in time taken to complete the test in whole seconds, 97% accuracy in the number of steps with an error of ± 1–2 steps and 87.5% accuracy in the distance covered with error of ± 0.50 meter. In the measure of time, the app was found to have equal sensitivity as an observer. In measure of number of steps and distance, the app demonstrated high sensitivity and precision (AUC > 0.9). The app also showed significant level of discrimination between healthy and gait-impaired individuals. Conclusion ‘Watkins’ and ‘Watkins2.0’ are efficient apps for objective performance of 10MWT and the TUG-test in NPH and LOVA patients and has application in several other pathologies characterised by gait and balance disturbance.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3