According to the characteristics of variable operating conditions and high
exhaust temperature of the refrigeration system of the refrigerator truck,
the change of the superheat at the outlet of the evaporator is adjusted by a
new electronic expansion valve, and a performance test-bed using the R404A
refrigerant is built to study the influence of the superheat at the outlet
of the evaporator on the performance of the refrigeration system of the
refrigerator truck. The results show that in the process of increasing the
superheat at the outlet of the evaporator, the outlet temperature of the
evaporator increases and the evaporation temperature decrease, the cooling
capacity of the system is reduced by 8.4%, and the COP of the system
increases first and then decreases; At this time, the optimal superheat at
the evaporator outlet is 6?C, and the system COP reaches the optimal value
of 2.856.
Publisher
National Library of Serbia
Reference22 articles.
1. Kwon, C., et al., Performance Evaluation of a Vapor Injection Heat Pump System for Electric Vehicles, International Journal of Refrigeration, 74 (2017), Feb., pp. 138-150
2. Zhong, H., et al., Study on the Influence of Evaporator Superheat and Evaporation Temperature on Supply Air Temperature in Car Air Conditioner, Fluid Machinery, 29 (2001), 4, pp. 50-52
3. Gruhle, W. D., et al. Modeling and Control of a Refrigerant Evaporator, Proceedings, 5th International Conference on Fluid Mechanics, New York, USA, 1985
4. Beghi, A., et al., A simulation Environment for Dry-Expansion Evaporators with Application to the Design of Autotuning Control Algorithms for Electronic Expansion Valves, International Journal of Refrigeration, 32 (2009), 7, pp. 1765-1775
5. Wang, D. D., et al., Heating Performance Characteristics of CO2 Heat Pump System for Electrical Vehicle in a Cold Climate, International Journal of Refrigeration, 85 (2018), Jan., pp. 27-41