The influence of stress hyperglycaemia on the prognosis of patients with acute myocardial infarction and temporary electrical cardiac pacing

Author:

Stojkovic Aleksandar1,Koracevic Goran1,Perisic Zoran1,Krstic Nebojsa1,Pavlovic Milan1,Todorovic Lazar1,Glasnovic Jozef1,Burazor Ivana1,Apostolovic Svetlana1,Nikolic Gordana2,Kostic Tomislav1,Brankovic Natasa3

Affiliation:

1. Klinika za kardiovaskularne bolesti, Klinički centar, Niš%SR13-03.05.45

2. Klinika za zaštitu mentalnog zdravlja, Klinički centar, Niš%SR13-03.05.58

3. Fakultet sporta i fizičkog vaspitanja, Niš%SR13-03.10

Abstract

Introduction. Elevated glucose levels on admission in many emergency conditions, including acute myocardial infarction (AMI), have been identified as a predictor of hospital mortality. Objective. Since there are no data in the literature related to stress hyperglycaemia (SH) in patients with both AIM and temporary electrical cardiac pacing, we aimed to investigate the influence of stress hyperglycaemia on the prognosis of patients with AMI and temporary electrical cardiac pacing. Methods. The prospective study included 79 patients with diagnosed AMI with ST-segment elevation (STEMI), admitted to the Coronary Care Unit of the Clinic for Cardiovascular Diseases, Clinical Centre Nis, from 2004 to 2007, who were indicated for temporary electrical cardiac pacing. The blood was sampled on admission for lab analysis, glucose levels were determined (as well as markers of myocardial necrosis - troponin I, CK-MB). Echocardiographic study was performed and ejection fraction was evaluated by using area length method. Results. The ROC analysis indicated that the best glycaemic level on admission, which could be used as a predictor of mortality, was 10.00 mmol/l, and the area under the curve was 0.82. In the group without SH, hospital mortality was 3-fold lower 11/48 (22.91%) compared to the group with SH 19/31 (61.29%), p<0.0001. Patients with SH were more likely to have higher troponin levels, Killip >1, lower ejection fraction and heart rate, as well as systolic blood pressure. Conclusion. The best cut-off value for SH in patients with AMI (STEMI) and temporary electrical cardiac pacing is 10 mmol/l (determined by ROC curve) and may be used in risk stratification; patients with glucose levels <10 mmol/l on admission are at 3-fold lower risk compared to those with glucose levels >10 mml/l. Our results suggest that SH is a more reliable marker of poor outcome in AMI patients with temporary pace maker, without previously diagnosed DM.

Publisher

National Library of Serbia

Subject

General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3