In this presented study, the cooling problem of the I.T.U. Triga Mark-II reactor has been handled and analyzed, and solutions were proposed. First of all, a thermal model of the reactor, heat exchanger, and cooling tower trio was established in the reactor. With this model, which was obtained with the help of experimental data, the parameters affecting the change of reactor water temperature over time were determined, and significant findings were obtained by investigating the possibilities of increasing the cooling power of the existing system. Then, using these mathematical equations, the effects of parameters that can affect the power of the reactor cooling system are investigated. The parameters affecting the cooling power are the cooling water flow rates in the second cooling circuits and the deposited layer that may exist as a result of numerical calculations. Different models have been created with machine learning algorithms (page regression, decision tree) to estimate the effect of the deposit layer. The mathematical and predictive models obtained with the experimental data for the heat transfer coefficient of the deposit layer, hbd, were compared. The pace regression algorithm modeled the hbd values with the least error rate (RMSE: 1.66) among the models. It has been calculated that the average tank water temperature will decrease by approximately 3.5?C if the deposits layer is cleared.
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Reference38 articles.
1. ***, General Atomic, Triga Mark-II Reactor Mechanical Operation and Maintenance, ITU, Istanbul, Turkey, 1978 2. Akay, O. E., Constituting the Thermal Model of Triga Mark II Nuclear Research Reactor Cooling System, Isi Bilim Ve Tek Dergisi, Journal Therm. Sci. Technol., 32 (2012), Jan., pp.109-116 3. Bouris, D., Bergeles, G., Numerical Calculation of the Effect of Deposit Formation on Heat-Exchanger Efficiency, Int. J. Heat Mass Transf., 40 (1997), 17, pp. 4073-4084 4. Baghdar Hosseini, S., et al., Experimental and Numerical Investigation on Particle Deposition in a Compact Heat Exchanger, Appl. Therm. Eng., 115 (2017), Mar., pp. 406-417 5. Guo, Z., et al., Mechanisms and Strategies for Ash Deposition Reduction in Flue Gas Heat Exchanger, Clean Technol Environ Policy, 24 (2022), June, pp. 77-93
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|