Abstract

Introduction/Objective. The essence of the treatment of degenerative knee joint diseases is pain relief, restoring motion range and stability of knee joints. Methods. In this study, 35 patients participated after having surgery of the knee joint. The patients had a posterior-stabilized (PS) endoprosthesis in one joint, and a posterior cruciate ligament retaining (CR) endoprosthesis in the other. Kinematic data was collected using a 3D optical system for tracking fluorescent markers in time. Based on these data, the following parameters were determined: degree of flexion, mediolateral (ML) translation, lateral gap, medial gap, and the angle of change between the transtibial and transfemoral axes. Results. The results show a more pronounced flexion degree with the PS prosthesis compared to the CR prosthesis. Also, the results show negligible values of the ML translation, lateral gap, and medial gap in both types of prostheses. Using the non-parameter Wilcoxon test, a substantial difference in the angle change between the transtibial and transfemoral axes was confirmed, that is, in the flexion angles on the CR and PS prostheses. Conclusion. This study shows that there is no great difference in the use of the PS or CR designs of endoprostheses. Better behavior and range of motion in the knee joint were established with the implantation of the PS endoprosthesis. This conclusion is confirmed by the substantial difference in the degree of flexion of the knee joint and in the position of the transversal axes of the tibia and femur.

Funder

Ministry of Education, Science and Technological Development of the Republic of Serbia

Publisher

National Library of Serbia

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparative gait analysis of parameters of the knee joint after CR and PS implantations;2022 11th Mediterranean Conference on Embedded Computing (MECO);2022-06-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3