Abstract
The mechanism of performance degradation of a natural gas combined cycle
(NGCC) power plant under high ambient temperature is studied by analysing
the performance characteristics and thermal properties of the working
fluids. Real operating data under typical seasonal conditions are collected
and studied. The results reveal that the power output of the NGCC system
decreases by 22.6 %, and the energy efficiency decreases from 57.28 % to
56.3 % when the ambient temperature increases from 5-35?C. GT total power
output and ST power output decrease by 17.0 % and 16.2 %, respectively, as
ambient temperature increases from 5-35 0C. The enthalpy difference of the
flue gas between the turbine inlet and outlet change slightly with varying
ambient temperature. The fuel and air input decrease by 16.0 % and 16.2 %,
respectively, as ambient temperature increases from 5-35?C. By analysing
the calculated results, the decrement in air and fuel input d is considered
as the immediate cause of system power output reduction. The proportion of
power consumed by AC reaches 50.4 % at 35?C. This is considered to be
caused by air compressor idle.
Publisher
National Library of Serbia
Subject
Renewable Energy, Sustainability and the Environment
Cited by
2 articles.
订阅此论文施引文献