Affiliation:
1. Yellow River Conservancy Technical Institute, Mechanical Engineering Department, Henan, Kaifeng, China
Abstract
In order to solve the problems of low temperature inside the greenhouse
caused by continuous haze weather or cloudy, rainy, and snowy weather, as
well as the large heat dissipation capacity and insufficient cross time heat
storage of existing solar greenhouses, by optimizing the design of the
external insulation materials and structure of the heat storage water tank
and studying the combination of heat storage working fluids, the greenhouse
heat storage device has achieved cross time heat storage and segmented slow
release heat release. The experiment shows that the combined heat insulation
effect of heat insulation coating + aerogel + rubber and plastic insulation
cotton is better, its 24-hour heat dissipation is reduced by 0.367 MJ
compared to a single insulation material. The heat preservation material of
the tank is 80~120 mm, and the cylinder heat storage tank is 6~10 m3 and
1:1. Which cannot only ensure a low effective heat dissipation rate, but
also control engineering. The results show that the composite phase change
material can increase the heat storage capacity, optimize the exothermic
process, and achieve the gradual release of heat.
Publisher
National Library of Serbia