Affiliation:
1. Faculty of Electrical Engineering, Belgrade
Abstract
The objective of the study presented in this paper is the analysis of influence of different buildup factor forms on a simulated radiographic image. Simulated radiographic images are obtained by means of the ray-tracing technique. Scattered photons are modelled using the generally accepted geometric progression form, linear form and tabulated data of buildup factors. Simulated images were compared to the reference results obtained by Monte Carlo calculation. The best agreement to Monte Carlo simulated images is achieved for the geometric progression form of buildup factor.
Publisher
National Library of Serbia
Subject
Safety, Risk, Reliability and Quality,Nuclear Energy and Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献