The use of an antibacterial implant in the treatment of periprosthetic infection in an HIV-positive patient

Author:

Nikolaev N. S.1ORCID,Malyuchenko L.  I.2ORCID,Karpukhin A. S.2ORCID,Yakovlev V. V.2ORCID,Maksimov A. L.2ORCID,Grigor'eva E. V.2ORCID,Rozhkov N. I.3ORCID

Affiliation:

1. Federal Center of Traumatology, Orthopedics and Arthroplasty; Chuvash State University named after I.N. Ulyanov

2. Federal Center of Traumatology, Orthopedics and Arthroplasty

3. National Ilizarov Medical Research Centre for Traumatology and Orthopedics

Abstract

Background: The frequency of occurrence of infectious complications after hip arthroplasty in HIV-infected patients is extremely high. Revision arthroplasty for periprosthetic infection is the leader (64%) among the causes of early revision interventions. The search for ways to increase the efficiency of the sanitizing stage of treatment due to antibacterial coatings of the endoprosthesis components continues.Objective: Demonstration of a clinical case of treatment of periprosthetic infection in an HIV-positive patient using a spacer and a femoral component of a hip joint endoprosthesis coated with linear Sp1 carbon chains and silver. 123 months after hip arthroplasty for stage 3 dysplastic coxarthrosis in HIV-positive patient of 42 years old developed an instability of the acetabular component with the growth of Staphylococcus aureus in punctates. A revision was performed with the removal of the endoprosthesis and the installation of an articulating spacer with the addition of antibiotics. 12 weeks later, a recurrence of periprosthetic infection occurred, and Enterococcus faecalis was detected in punctates. During re-endoprosthetics, there was an installation of an articulating spacer covered with a two-dimensionally ordered linear-chain carbon doped with silver, based on the Zimmer CPT femoral component and bone cement with antibiotics addition. After 3 months, the second stage of revision arthroplasty was performed with implantation of an individual acetabular component and a femoral component coated with two-dimensionally ordered linear-chain carbon doped with silver.Conclusion: 4 months after the operation the patient returned to work, 12 months later the functional results were satisfactory. The use of components coated with two-dimensionally ordered linear-chain carbon doped with silver in an HIV-positive patient with recurrent periprosthetic infection made it possible to stop the infectious process, improve limb function and the quality of life.

Publisher

Scientific Research Institute - Ochapovsky Regional Clinical Hospital No 1

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3