Elution of Monomers From CAD-CAM Materials and Conventional Resin Composite in Distilled Water and Artificial Saliva

Author:

Mourouzis P1,Diamantopoulou E-I2,Plastiras O3,Samanidou V4,Tolidis K5

Affiliation:

1. *Petros Mourouzis, MSc, PhD, assistant professor, Department of Operative Dentistry, Division of Dental Tissues Pathology and Therapeutics, Faculty of Dentistry, Aristotle University of Thessaloniki, Greece

2. Ellisavet-Ioanna Diamantopoulou, MSc, Department of Chemistry, Laboratory of Analytical Chemistry, Aristotle University of Thessaloniki, Greece

3. Orfeas Plastiras, MSc, Department of Chemistry, Laboratory of Analytical Chemistry, Aristotle University of Thessaloniki, Greece

4. Victoria Samanidou, PhD, professor, Department of Chemistry, Laboratory of Analytical Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece

5. Kosmas Tolidis, PhD, professor, Department of Operative Dentistry, Division of Dental Tissues Pathology and Therapeutics, Faculty of Dentistry, Aristotle University of Thessaloniki, Greece.

Abstract

SUMMARY Purpose The purpose of this study was to evaluate the leaching pattern of different types of polymer computer-aided design and computer-aided manufacturing (CAD-CAM) materials with a conventional resin composite. Methods and Materials Specimens of three representatives by type of polymer CAD-CAM blocks and one conventional resin composite were suspended using a silk thread in distilled water and artificial saliva. After one day, seven days, 14 days, 30 days, and 60 days, the analysis of the eluates for the detection of bisphenol A (BPA), urethane dimethacrylate (UDMA), triethylene glycol dimethacrylate (TEGDMA) and bisphenol A-glycidyl dimethacrylate (Bis-GMA) was quantified by utilizing high-performance liquid chromatography (HPLC). Results TEGDMA was the main eluted monomer for the polymer CAD-CAM materials for both solutions. However, there was a decreasing pattern throughout the tested period. On the contrary, there was a constant release of monomers from the conventional resin composite. Bisphenol-A was released only by the conventional resin composite and in both solutions chosen. Conclusions Different types of polymer CAD-CAM materials release minimal or no monomers compared to the conventional resin composite material. The methods of fabrication of polymer CAD-CAM materials produces better properties than the conventional resin composite with a dramatic decrease of monomer elution.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3