Evaluation of the Radiopacities of Bulk-fill RestorativesUsing Two Digital Radiography Systems

Author:

Yasa E1,Yasa B1,Aglarci OS2,Ertas ET3

Affiliation:

1. Elif Yasa, DDS, PhD, Sifa University, Faculty of Dentistry, Department of Restorative Dentistry, Izmir, Turkey

2. Osman Sami Aglarci, DDS, PhD, Sifa University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Izmir, Turkey

3. Elif Tarim Ertas, DDS, PhD, Izmir Katip Celebi University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Izmir, Turkey

Abstract

SUMMARY This study investigated the radiopacity values of bulk-fill restoratives by using two digital radiography systems. Nine bulk-fill restoratives and a conventional composite were used in the study. Six disc-shaped specimens were prepared from each of these materials, three each at thicknesses of 1 mm and 2 mm, and tooth slices with these same thicknesses were obtained. As a control, an aluminum step wedge varying in thickness from 0.5 to 10 mm in was used. Three specimens of each of the materials, together with the tooth slice and the aluminum step wedge, were placed over a complementary metal oxide semiconductor (CMOS) sensor and a storage photostimulable phosphor (PPS) plate system and exposed using a dental x-ray unit. The images were analyzed using a software program to measure the mean gray values (MGVs). Five measurements were obtained from each of the restorative materials, the enamel, the dentin, and the stepwedge. The MGVs were converted to the equivalent aluminum thicknesses. Three-way analysis of variance (ANOVA) was used to determine the significance of the differences among the groups. A Tukey test was applied for pairwise comparisons (p<0.05). All composite-based restoratives were found to have greater radiopacities than enamel or dentin. Equia Fil had the lowest radiopacity value. Radiopacity increased as the thicknesses of the restorative material increased. The CMOS system showed significantly higher radiopacity values than the PSP system. In conclusion, all investigated bulk-fill restoratives passed the International Organization for Standardization and American National Standard Institute/American Dental Association requirements for radiopacity values when evaluated with the two digital radiography systems.

Publisher

Operative Dentistry

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3