Mechanical Properties and Simulated Wear of Provisional Resin Materials

Author:

Takamizawa T1,Barkmeier WW2,Tsujimoto A3,Scheidel D4,Erickson RL5,Latta MA6,Miyazaki M7

Affiliation:

1. Toshiki Takamizawa, DDS, PhD, Nihon University School of Dentistry, Operative Dentistry, Tokyo, Japan

2. Wayne W Barkmeier, DDS, MS, Creighton University School of Dentistry, General Dentistry, Omaha, NE, USA

3. Akimasa Tsujimoto, DDS, PhD, Nihon University School of Dentistry, Operative Dentistry, Tokyo, Japan

4. Donal Scheidel, DDS, Creighton University School of Dentistry, Diagnostic Sciences, Omaha, NE, USA

5. Robert L Erickson, PhD, DDS, Creighton University School of Dentistry, General Dentistry, Omaha, NE, USA

6. Mark A Latta, DMD, MS, Creighton University, School of Dentistry, General Dentistry, Omaha, NE, USA

7. Masashi Miyazaki, DDS, PhD, Nihon University School of Dentistry, Operative Dentistry, Tokyo, Japan

Abstract

SUMMARY The purpose of this study was to determine flexural properties and erosive wear behavior of provisional resin materials. Three bis-acryl base provisional resins—1) Protemp Plus (PP), 2) Integrity (IG), 3) Luxatemp Automix Plus (LX)—and a conventional poly(methylmethacrylate) (PMMA) resin, UniFast III (UF), were evaluated. A resin composite, Z100 Restorative (Z1), was included as a benchmark material. Six specimens for each of the four materials were used to determine flexural strength and elastic modulus according to ISO Standard 4049. Twelve specimens for each material were used to examine wear using a generalized wear simulation model. The test materials were each subjected to wear challenges of 25,000, 50,000, 100,000, and 200,000 cycles in a Leinfelder-Suzuki (Alabama) wear simulator. The materials were placed in custom cylinder-shaped stainless-steel fixtures, and wear was generated using a cylindrical-shaped flat-ended stainless-steel antagonist in a slurry of nonplasticized PMMA beads. Wear (mean facet depth [μm] and volume loss [mm3]) was determined using a noncontact profilometer (Proscan 2100) with Proscan and AnSur 3D software. The laboratory data were evaluated using two-way analysis of variance (ANOVA; factors: 1) material and 2) cycles) followed by Tukey HSD post hoc test (α=0.05). The flexural strength ranged from 68.2 to 150.6 MPa, and the elastic modulus ranged from 2.0 to 15.9 GPa. All of the bis-acryl provisional resins (PP, IG, and LX) demonstrated significantly higher values than the PMMA resin (UF) in flexural strength and elastic modulus (p<0.05). However, there was no significant difference (p>0.05) in flexural properties among three bis-acryl base provisional resins (PP, IG, and LX). Z1 demonstrated significantly (p<0.05) higher flexural strength and elastic modulus than the other materials tested. The results for mean facet wear depth (μm) and standard deviations (SD) for 200,000 cycles were as follows: PP, 22.4 (5.0); IG, 51.0 (6.5); LX, 63.7 (4.5); UF, 70.5 (8.0); and Z1, 7.6 (1.2). Volume loss (mm3) and SDs for 200,000 cycles were as follows: PP, 0.311 (0.049); IG, 0.737 (0.074); LX, 0.919 (0.053); UF, 1.046 (0.127); and Z1, 0.111 (0.017). The two-way ANOVA showed a significant difference among materials (p<0.001) and number of cycles for both facet depth and volume loss. The post hoc test revealed differences (p<0.05) in wear values among the tested materials examined in this study. The findings provide valuable information regarding the flexural properties and the relative wear behavior of the provisional resins examined in this study.

Publisher

Operative Dentistry

Subject

General Dentistry

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3