In vitro biomechanical testing of different configurations of acrylic external skeletal fixator constructs

Author:

Tyagi S. K.,Kinjavdeka P.,Amarpal Sharma,Pawde A. M.,Srivastava T.,Singh J.,Madhu D. N.,Aithal H. P.

Abstract

SummaryObjective: To evaluate the in vitro biomechanical properties of four different configurations of acrylic external skeletal fixator constructs.Materials and methods: Simulated bone constructs were prepared using two segments of 20 mm ultra-high-density polyethylene rods with a gap of 5 mm. The full pins (1.5 mm) were passed through the proximal and distal segments of ultra-high-density polyethylene rods, in the same plane, parallel to each other in configuration U, and were crossed in the M1, M2 and C configurations at a 90° angle to each other. Configuration U was a single bilateral uniplanar construct, M1 was a double orthogonal bilateral construct, M2 was a double orthogonal bilateral construct with proximal and distal connecting articulations, and C was a double orthogonal bilateral construct with proximal and distal circumferential articulations. Temporary scaffolds of different external skeletal fixator configurations were constructed using commercially available polyvinyl chloride pipes (20 mm) connected and secured to the fixation pins at a fixed distance from the rods. Acrylic powder (polymer) mixed with liquid (monomer) was poured into the pipes and allowed to solidify to form the side bars and rings. The external skeletal fixator constructs were then subjected to axial compression, cranio-caudal three-point bending and torsion (n = 4 each) using a universal testing machine. Mechanical parameters, namely stress, strain, modulus of elasticity, stiffness and bending moment of fixator constructs, were determined from load-displacement curves.Results: Configuration U was the weakest and configuration C was the strongest under all the testing modes. Under compression, the M1, M2 and C configurations were similar. Under bending, a significant difference was observed among the uniplanar, multi -planar and circular configurations with no difference between M1 and M2. However, under torsion, all the external skeletal fixator configurations differed significantly.Clinical significance: The freeform external skeletal fixator using acrylic as a replacement for a metallic bar may be useful to treat bone fractures and luxations in small animals, as it is mechanically strong, lightweight, economical, and pins can be passed from any direction depending upon the clinical situation.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3