Large animal ventilator-integrated volumetric capnography generates clinically acceptable values of physiologic dead space in anesthetized healthy adult horses

Author:

Frampton Alycia1,Floriano Dario1,Simpson Keith1,Hopster Klaus1

Affiliation:

1. Department of Clinical Studies – New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA

Abstract

Abstract OBJECTIVE To evaluate the agreement between the Tafonius large animal ventilator-integrated volumetric capnography (vCap) software and the Respironics NICO noninvasive cardiac output monitor reference system. ANIMALS Data were collected from 56 healthy adult horses undergoing general anesthesia. METHODS Animals were placed under general anesthesia and connected to the Tafonius large animal ventilator circle system. A flow partitioning device with CO2 and flow sensors was utilized to couple the endotracheal tube to the NICO monitor. Tafonius CO2 and flow sensors are incorporated into the Y-piece of the breathing circuit. Arterial blood samples were collected to determine the partial pressure of arterial carbon dioxide (PaCO2) immediately before data collection. The PaCO2 was input into the Tafonius and NICO monitor, and dead space ventilation (%Vd), end-tidal CO2 partial pressure (ETco2), mixed-expired CO2 partial pressure (Peco2), and expired tidal volume (Vt) were calculated over a single breath. Multiple measurements were completed for each patient, with a total of 200 paired data points collected for analysis. Data were assessed for normality, and Bland-Altman analysis was performed. Bias and 95% limits of agreement were calculated. RESULTS The limits of agreement for %Vd of the ventilator-derived measurements fell within ± 10% of the NICO monitor reference method. CLINICAL RELEVANCE Our results indicate that, when compared to the NICO monitor method, the Tafonius-integrated vCap software provides clinically acceptable values of Peco2, Vt, and %Vd in healthy adult horses.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Reference40 articles.

1. Atelectasis causes gas exchange impairment in the anaesthetised horse;Nyman G,1990

2. Ventilation-perfusion relationships in the anaesthetised horse;Nyman G,1989

3. Variety of non-invasive continuous monitoring methodologies including electrical impedance tomography provides novel insights into the physiology of lung collapse and recruitment – case report of an anaesthetized horse;Moens Y,2014

4. Validation of Bohr dead space measured by volumetric capnography;Tusman G,2011

5. Volumetric capnography: lessons from the past and current clinical applications;Verscheure S,2016