Prolonged holding time and sampling protocol affects viscoelastic coagulation parameters as measured by the VCM-Vet™ using fresh equine native whole blood

Author:

Díaz Yucupicio Sandra1,Bishop Rebecca C.1,Fick Meghan E.1,Austin Scott M.1,Barger Anne M.1,Stolsworth Bailey1,Wilkins Pamela A.1

Affiliation:

1. Department of Veterinary Clinical Medicine, University of Illinois at Urbana Champaign, Urbana, IL

Abstract

Abstract OBJECTIVES Determine the effect of sample holding time and single sample reuse on viscoelastic coagulation parameters when using fresh equine native whole blood. ANIMALS 8 healthy adult horses from a university teaching herd. PROCEDURES Blood collected by direct jugular venipuncture (18 ga needle, 3 mL syringe) was held at 37 °C for 2, 4, 6, or 8 minutes according to 1 of 2 protocols. Syringes were gently inverted twice, a small amount of blood was expressed, testing cartridges were filled, and placed within the VCM-Vet™ device (Entegrion Inc). Protocol A: samples were processed from a single syringe. Protocol B: 4 syringes were drawn through a single needle. VCM-Vet™ measures assessed included clot time (CT), clot formation time (CFT), alpha angle (AA), amplitude at 10/20 minutes (A10/A20), maximal clot firmness (MCF), and lysis index at 30/45 minutes (LI30/LI45). Differences over time were examined using the Friedman test and post hoc Wilcoxon Rank Sum Test with Bonferroni correction, P ≤ .05. RESULTS Following Protocol A, there was a significant effect of holding time for CT (P = .02), CFT (P = .04), and AA (P = .05). CT and AA decreased over time, while CFT increased. Samples handled by Protocol B showed no significant difference over time for any of the VCM-Vet™ parameters. CLINICAL RELEVANCE Sample holding time and handling protocol impact VCM-Vet™ testing results of fresh equine native whole blood. Viscoelastic coagulation samples tested using the VCM-Vet™ may be held unagitated for up to 8 minutes after collection while warm, but should not be reused.

Publisher

American Veterinary Medical Association (AVMA)

Subject

General Veterinary,General Medicine

Reference34 articles.

1. A cell-based model of hemostasis;Hoffman M,2001

2. Coagulopathy in the equine critical care patient;Dallap BL,2004

3. Use of thromboelastography in clinical practice;Burton AG,2020

4. Application of thrombelastography/thromboelastometry to veterinary medicine;Kol A,2010

5. Clinicopathologic evidence of disseminated intravascular coagulation in horses with acute colitis;Dolente BA,2002