The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants

Author:

Deere Kevin1,Matharu Gulraj S.1,Ben-Shlomo Yoav2,Wilkinson J. Mark3,Blom Ashley W.14,Sayers Adrian1,Whitehouse Michael R.14

Affiliation:

1. Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK

2. Department of Population Health Sciences, University of Bristol, Bristol, UK

3. Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK

4. National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK

Abstract

Aims A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. Methods Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. Results There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. Conclusion CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359–367.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference40 articles.

1. Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases

2. Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030

3. No authors listed. Knee & Shoulder Arthroplasty Annual Report. Australian Orthopaedic Association National Joint Replacement Registry. 2018. https://aoanjrr.sahmri.com/annual-reports-2018 (date last accessed 8 December 2021).

4. No authors listed. 16th Annual Report. National Joint Registry for England, Wales, Northern Ireland and the Isle of Man. 2019. https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR 16th 20Annual 20Report 2019.pdf (date last accessed 8 December 2021).

5. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales