Cytokine levels in synovial fluid from hips with well-functioning or loose prostheses

Author:

Nivbrant B.1,Karlsson K.2,Kärrholm J.3

Affiliation:

1. Department of Orthopaedics

2. Department of Clinical Chemistry, Ume̊ University Hospital, Ume̊ S-901 85, Sweden.

3. Department of Orthopaedics, Sahlgren University Hospital, 415 45 Gothenburg, Sahlgrenska, Sweden.

Abstract

We analysed synovial fluid from 88 hips, 38 with osteoarthritis and 12 with well-functioning and 38 with loose hip prostheses. The levels of TNF-α, IL-1ß (71 hips) and IL-6 (45 hips) were measured using the ELISA technique. Joints with well-functioning or loose prostheses had significantly increased levels of TNF-α compared with those with osteoarthritis. Hips with aseptic loosening also had higher levels of IL-1ß but not of IL-6 compared with those without an implant. The levels of TNF-α and IL-1ß did not differ between hips with stable and loose prostheses. Higher levels of TNF-α were found in hips with bone resorption of type II and type III (Gustilo-Pasternak) compared with those with type-I loosening. The level of cytokines in joint fluid was not influenced by the time in situ of the implants or the age, gender or area of the osteolysis as measured on conventional radiographs. Our findings support the theory that macrophages in the joint capsule increase the production of TNF-α at an early phase probably because of particle load and in the absence of clinical loosening. Since TNF-α has an important role in the osteolytic process, the interfaces should be protected from penetration of joint fluid.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The effect of TNF-α on osteoblasts in metal wear-induced periprosthetic bone loss;Bone & Joint Research;2020-11-01

2. Synovial Fluid from Aseptically Failed Total Hip or Knee Arthroplasty is Not Toxic to Osteoblasts;Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca;2010-10-01

3. Femoral stem wear in cemented total hip replacement;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2008-05-01

4. Expression profiling reveals alternative macrophage activation and impaired osteogenesis in periprosthetic osteolysis;Journal of Orthopaedic Research;2007-08-29

5. Plasma Cytokines as Markers of Aseptic Prosthesis Loosening;Clinical Orthopaedics & Related Research;2006-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3