Revision rate in metal compared to ceramic humeral head total shoulder arthroplasty and hemiarthroplasty

Author:

Davies Andrew1ORCID,Sabharwal Sanjeeve2,Liddle Alexander D.23,Zamora Talaya Maria B.3,Rangan Amar4,Reilly Peter12

Affiliation:

1. Department of Bioengineering, Imperial College London, London, UK

2. Department of Trauma & Orthopaedics, Imperial College Healthcare NHS Trust, London, UK

3. Department of Surgery and Cancer, Imperial College London, London, UK

4. Department of Health Sciences, University of York, York, UK

Abstract

AimsMetal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey.MethodsNJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.ResultsA total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure.ConclusionThe rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.Cite this article: Bone Joint J 2024;106-B(5):482–491.

Publisher

British Editorial Society of Bone & Joint Surgery

Reference34 articles.

1. History of shoulder arthroplasty;Jaap Willems;J Arthrosc Jt Surg,2021

2. Prosthetic bearing surfaces in anatomic and reverse total shoulder arthroplasty;Stone;J Am Acad Orthop Surg,2021

3. Ben-Shlomo Y , Blom A , Clark E , et al. National Joint Registry 20th Annual Report , National Joint Registry for England, Wales, Northern Ireland, Isle of Man and States of Guernsey . 2023 . https://reports.njrcentre.org.uk/Portals/0/PDFdownloads/NJR%2020th%20Annual%20Report%202023.pdf ( date last accessed 23 February 2024 ).

4. New prospects for a prolonged functional life-span of artificial hip joints by using the material combination polyethylene/aluminium oxide ceramin/metal;Semlitsch;J Biomed Mater Res,1977

5. Influence of humeral head material on wear performance in anatomic shoulder joint arthroplasty;Mueller;J Shoulder Elbow Surg,2017

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献